A third generation tomography system with fifteen detectors simulated by Monte Carlo method
Carregando...
Data
Data de publicação
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Brazilian Journal of Radiation Sciences
Resumo
This paper describes the Monte Carlo simulation, using MCNP4C, of a multichannel third generation tomography system containing a two radioactive sources 192I (316.5 – 468 KeV) and 137Cs (662 KeV), and a set of fifteen NaI(Tl) detectors, with dimensions of 1 inch diameter and 2 inches thick, in fan beam geometry, positioned diametrically opposite. Each detector moves 10 steps of 0,24o, totalizing 150 virtual detectors per projection, and then the system rotate 2 degrees. The Monte Carlo simulation was performed to evaluate the viability of this configuration. For this, a multiphase phantom containing polymethyl methacralate (PMMA (( 1.19 g/cm3)), iron ( 7.874 g/cm3), aluminum ( 2.6989 g/cm3) and air ( 1.20479E-03 g/cm3) was simulated. The simulated number of histories was 1.1E+09 per projection and the tally used were the F8, which gives the pulse height of each detector. The data obtained by the simulation was used to reconstruct the simulated phantom using the statistical iterative Maximum Likelihood Estimation Method Technique (ML-EM) algorithm. Each detector provides a gamma spectrum of the sources, and a pulse height analyzer (PHA) of 10% on the 316.5 KeV and 662 KeV photopeaks was performed. This technique provides two reconstructed images of the simulated phantom. The reconstructed images provided high spatial resolution, and it is supposed that the temporal resolution (spending time for one complete revolution) is about 2.5 hours.
Como referenciar
VELO, A.F.; ALVAREZ, A.G.; CARVALHO, D.V..S.; FERNANDEZ, V.; SOMESSARI, S.; SPRENGER, F.F.; HAMADA, M.M.; MESQUITA, C.H. A third generation tomography system with fifteen detectors simulated by Monte Carlo method. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-13, 2019. DOI: 10.15392/bjrs.v7i2A.708. Disponível em: http://repositorio.ipen.br/handle/123456789/29925. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.