Optimization of a coincidence system using plastic scintillators in 4 'pi' geometry

dc.contributor.authorDIAS, M.S.pt_BR
dc.contributor.authorPIUVEZAM FILHO, H.pt_BR
dc.contributor.authorKOSKINAS, M.F.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:42:44Zpt_BR
dc.date.accessioned2014-07-30T11:51:53Z
dc.date.available2014-07-15T13:42:44Zpt_BR
dc.date.available2014-07-30T11:51:53Z
dc.date.issued2008pt_BR
dc.description.abstractImprovements recently developed at the Nuclear Metrology Laboratory of IPEN-CNEN/SP in São Paulo were performed in order to increase the detector efficiency of a 4πβ−γ coincidence primary system using plastic scintillators in 4π geometry. Measurements were undertaken and compared to the original system and Monte Carlo simulations of the extrapolation curves were calculated for this new system and compared to experimental results. For this purpose, the code Penelope was applied for calculating response functions for each detector and the code Esquema, developed at LMN, was used for simulating the decay scheme processes.
dc.format.extent905-908pt_BR
dc.identifier.citationDIAS, M.S.; PIUVEZAM FILHO, H.; KOSKINAS, M.F. Optimization of a coincidence system using plastic scintillators in 4 'pi' geometry. <b>Applied Radiation and Isotopes</b>, v. 66, n. 6-7, p. 905-908, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.apradiso.2008.02.033">10.1016/j.apradiso.2008.02.033</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/4967.
dc.identifier.doi10.1016/j.apradiso.2008.02.033
dc.identifier.fasciculo6-7pt_BR
dc.identifier.issn0969-8043pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8407-9833
dc.identifier.orcidhttps://orcid.org/0000-0003-2478-5757
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/4967pt_BR
dc.identifier.vol66pt_BR
dc.relation.ispartofApplied Radiation and Isotopespt_BR
dc.rightsopenAccessen
dc.sourceApresentado em: International Conference on Radionuclide Metrology and its Applications, 16th, Cape Town, South Africa, 03-07 September, 2007pt_BR
dc.subjectlow dose irradiationpt_BR
dc.subjectextrapolation chamberspt_BR
dc.subjectradiotherapypt_BR
dc.subjectdose ratespt_BR
dc.subjectradiation sourcespt_BR
dc.subjectx radiationpt_BR
dc.subjectbeta dosimetrypt_BR
dc.titleOptimization of a coincidence system using plastic scintillators in 4 'pi' geometrypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARINA FALLONE KOSKINAS
ipen.autorHELIO PIUVEZAM FILHO
ipen.autorMAURO DA SILVA DIAS
ipen.codigoautor1387
ipen.codigoautor3333
ipen.codigoautor1292
ipen.contributor.ipenauthorMARINA FALLONE KOSKINAS
ipen.contributor.ipenauthorHELIO PIUVEZAM FILHO
ipen.contributor.ipenauthorMAURO DA SILVA DIAS
ipen.date.recebimento09-05pt_BR
ipen.identifier.fi1.114pt_BR
ipen.identifier.ipendoc13769pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication420a8816-64da-4bb8-a1c4-5b8b638033b1
relation.isAuthorOfPublication1537deb2-f766-4dc2-a358-fe573f925c02
relation.isAuthorOfPublication58653850-db59-4051-aa72-5c32a5f6670e
relation.isAuthorOfPublication.latestForDiscovery58653850-db59-4051-aa72-5c32a5f6670e
sigepi.autor.atividadeDIAS, M.S.:1292:310:Spt_BR
sigepi.autor.atividadePIUVEZAM FILHO, H.:3333:-1:Npt_BR
sigepi.autor.atividadeKOSKINAS, M.F.:1387:310:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13769.pdf
Tamanho:
502.84 KB
Formato:
Adobe Portable Document Format

Coleções