Efficiency loss in HPGe detectors due to beta and gamma sum coincidence

dc.contributor.authorCASTRO, RUY M.pt_BR
dc.contributor.authorVANIN, VITO R.pt_BR
dc.contributor.authorMAIDANA, NORA L.pt_BR
dc.contributor.authorPASCHOLATI, PAULO R.pt_BR
dc.contributor.authorDIAS, MAURO S.pt_BR
dc.contributor.authorKOSKINAS, MARINA F.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-31T11:33:40Zpt_BR
dc.date.accessioned2014-07-31T11:55:30Z
dc.date.available2014-07-31T11:33:40Zpt_BR
dc.date.available2014-07-31T11:55:30Z
dc.date.issued2005pt_BR
dc.description.abstractAmong the secondary detection effects in gamma-ray spectroscopy with HPGe detectors that reduce the peak area and must be properly taken into account in accurate measurements, the less well known is counting loss by beta and gamma-ray sum coincidence. The fraction of lost counts was estimated assuming that a photon detection event can sum either with the coincident beta-ray or its bremsstrahlung in the detector capsule or surrounding materials. The beta-ray was tracked through all the materials between source and detector. The result was calculated as a sequence of integral expressions evaluated numerically, without resorting to simulation. It is shown that the counting losses due to this effect are negligible for most calibration sources in typical detector arrangements.
dc.format.extent754-756pt_BR
dc.identifier.citationCASTRO, RUY M.; VANIN, VITO R.; MAIDANA, NORA L.; PASCHOLATI, PAULO R.; DIAS, MAURO S.; KOSKINAS, MARINA F. Efficiency loss in HPGe detectors due to beta and gamma sum coincidence. <b>Brazilian Journal of Physics</b>, v. 35, n. 3B, p. 754-756, 2005. DOI: <a href="https://dx.doi.org/10.1590/S0103-97332005000500008">10.1590/S0103-97332005000500008</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/7671.
dc.identifier.doi10.1590/S0103-97332005000500008
dc.identifier.fasciculo3Bpt_BR
dc.identifier.issn0103-9733pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8407-9833
dc.identifier.orcidhttps://orcid.org/0000-0003-2478-5757
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/7671pt_BR
dc.identifier.vol35pt_BR
dc.relation.ispartofBrazilian Journal of Physicspt_BR
dc.rightsopenAccessen
dc.subjecthigh-purity ge detectorspt_BR
dc.subjectefficiencypt_BR
dc.subjectlossespt_BR
dc.subjectcounting techniquespt_BR
dc.subjectgamma spectroscopypt_BR
dc.subjectbeta decaypt_BR
dc.subjectcoincidence methodspt_BR
dc.subjectcalibrationpt_BR
dc.titleEfficiency loss in HPGe detectors due to beta and gamma sum coincidencept_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARINA FALLONE KOSKINAS
ipen.autorMAURO DA SILVA DIAS
ipen.codigoautor1387
ipen.codigoautor1292
ipen.contributor.ipenauthorMARINA FALLONE KOSKINAS
ipen.contributor.ipenauthorMAURO DA SILVA DIAS
ipen.date.recebimento06-09pt_BR
ipen.identifier.fi0.445pt_BR
ipen.identifier.ipendoc11382pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication420a8816-64da-4bb8-a1c4-5b8b638033b1
relation.isAuthorOfPublication58653850-db59-4051-aa72-5c32a5f6670e
relation.isAuthorOfPublication.latestForDiscovery58653850-db59-4051-aa72-5c32a5f6670e
sigepi.autor.atividadeDIAS, MAURO S.:1292:6:Npt_BR
sigepi.autor.atividadeKOSKINAS, MARINA F.:1387:6:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
11382.pdf
Tamanho:
198.95 KB
Formato:
Adobe Portable Document Format

Coleções