Influence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodology

dc.contributor.authorKUAHARA, L.T.
dc.contributor.authorCORREA, E.L.
dc.contributor.authorCARNEIRO, R.C.G.
dc.contributor.authorBEZERRA, R.R.L.
dc.contributor.authorPOTIENS, M.P.A.
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-03-11T11:43:12Z
dc.date.available2019-03-11T11:43:12Z
dc.date.issued2019pt_BR
dc.description.abstractIn this study we present a new “in situ” calibration methodology establishment for activimeters – i.e., this equipment calibration can be made at the hospital and/or the nuclear medicine service (NMS) – and also the importance of considering vials radioactive residue when generating the calibration coefficient in terms of activity (NA). For the calibration, two methods are presented here: in the first, 99mTc sample activity (AC) is measured in the NMS. Then it is sent to the Instruments Calibration Laboratory (LCI/IPEN) where the reference activity (AR) is obtained under controlled conditions in a reference vial. After geometry and residue corrections, NA is calculated. In the second method, AR is obtained at the LCI, then 99mTc sample is sent to the hospital/NMS, where AC is measured and NA calculated. Calibration methodologies were applied to three NMS and to four equipment belonging to the radiopharmaceutical production facility (CR) at the Nuclear and Energy Research Institute (IPEN). Both methodologies were tested with and without residual activity corrections under controlled conditions. Variations of up to 4% were obtained.pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipIDCAPES: 2215/2013pt_BR
dc.description.sponsorshipIDCNPq: 312131/2016-0pt_BR
dc.description.sponsorshipIDFAPESP: 15/19584-8pt_BR
dc.format.extent291-293pt_BR
dc.identifier.citationKUAHARA, L.T.; CORREA, E.L.; CARNEIRO, R.C.G.; BEZERRA, R.R.L.; POTIENS, M.P.A. Influence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodology. <b>Radiation Physics and Chemistry</b>, v. 155, p. 291-293, 2019. SI. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2018.06.021">10.1016/j.radphyschem.2018.06.021</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29776.
dc.identifier.doi10.1016/j.radphyschem.2018.06.021pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfi60.153pt_BR
dc.identifier.percentilfiCiteScore73.00
dc.identifier.suplementoSIpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29776
dc.identifier.vol155pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjectradioactive wastes
dc.subjectcalibration
dc.subjectnuclear medicine
dc.subjectradiopharmaceuticals
dc.subjectactivity meters
dc.subjectlaboratory equipment
dc.subjectcalibration standards
dc.titleInfluence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodologypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorREGINA CELIA GORNI CARNEIRO
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorREGINA RIBEIRO DE LIMA BEZERRA
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorLILIAN TOSHIE KUAHARA
ipen.codigoautor9688
ipen.codigoautor346
ipen.codigoautor478
ipen.codigoautor7498
ipen.codigoautor10859
ipen.contributor.ipenauthorREGINA CELIA GORNI CARNEIRO
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorREGINA RIBEIRO DE LIMA BEZERRA
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorLILIAN TOSHIE KUAHARA
ipen.date.recebimento19-03pt_BR
ipen.identifier.fi2.226pt_BR
ipen.identifier.fiCiteScore3.7
ipen.identifier.ipendoc25107pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationeeb93a04-3c32-4fb2-9d9e-c8613a095781
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication7fbc6976-4b2d-4f93-80fe-b810f52c0352
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublication44381d85-6097-40f4-b9a3-9e991b7bebe5
relation.isAuthorOfPublication.latestForDiscovery44381d85-6097-40f4-b9a3-9e991b7bebe5
sigepi.autor.atividadeKUAHARA, L.T.:10859:330:Spt_BR
sigepi.autor.atividadeCORREA, E.L.:7498:330:Npt_BR
sigepi.autor.atividadeCARNEIRO, R.C.G.:9688:110:Npt_BR
sigepi.autor.atividadeBEZERRA, R.R.L.:478:110:Npt_BR
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25107.pdf
Tamanho:
413.82 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções