Improvements in the quality control of iridium-192 wire used in brachytherapy

dc.contributor.authorCOSTA, OSVALDO L.pt_BR
dc.contributor.authorZEITUNI, CARLOS A.pt_BR
dc.contributor.authorROSTELATO, MARIA E.C.M.pt_BR
dc.contributor.authorMOURA, JOÃO A.pt_BR
dc.contributor.authorFEHER, ANSELMOpt_BR
dc.contributor.authorMOURA, EDUARDO S.pt_BR
dc.contributor.authorSOUZA, CARLA D.pt_BR
dc.contributor.authorSOMESSARI, SAMIR L.pt_BR
dc.contributor.editorDUDALA, JOANNApt_BR
dc.contributor.editorSTEGOWSKI, ZDZISLAWpt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON DEVELOPMENT AND APPLICATIONS OF NUCLEAR TECHNOLOGIESpt_BR
dc.date.accessioned2022-10-27T17:59:42Z
dc.date.available2022-10-27T17:59:42Z
dc.date.eventoSeptember 11-14, 2011pt_BR
dc.description.abstractBrachytherapy is a method used in the treatment of cancerous tumors by ionizing radiation produced by sources introduced into the tumor area, this method seeks a more direct attack to the tumor, thereby maximizing the radiation dose to diseased tissue while minimizing the dose to healthy tissues (1). One of the radionuclides used in brachytherapy is iridium-192. The Radiation Technology Center (CTR) of the Nuclear and Energy Research Institute (IPEN) has produced commercially, since 1998, iridium-192 wires used in low dose rate (LDR) brachytherapy (2). To produce this radionuclide, firstly a iridium-platinum wire is irradiated in the nuclear reactor IEA-R1 for 30 hours with a neutron flux of 5 x 1013 ncm-2s-1, the wire is left to decay by 30 days to remove the main contaminants and then goes through a quality control before being sent to the hospital. In this quality control is checked the radiation homogeneity along each centimeter of the wire (3). To implement this procedure is used a device consisting of an ionization chamber surrounded by a lead shield with a small 1 cm wide slit, linked to the ionization chamber is a voltage source and a Keithley 617 electrometer, 2 minutes is the range used to measure the charge by the electrometer. The iridium wire is considered in accordance when there is no variation greater than 5% between the average measures and the maximum and minimum values. However, due to design features of the measurement system, the wire may appear to the detector through the slit in larger sizes than the ideal, improperly influencing the final quality control. This paper calculates the difference in size of these variations in profile and their influence on the final count, it compares the actual values obtained and describes the improvements made in quality control procedures that provided more accurate measurement data, analyzes the results and suggests changes in devices aimed at further improving the quality control of iridium-192 wires produced at IPEN and used in hospitals in Brazil.pt_BR
dc.event.siglaNUTECHpt_BR
dc.format.extent126-126pt_BR
dc.identifier.citationCOSTA, OSVALDO L.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.; MOURA, JOÃO A.; FEHER, ANSELMO; MOURA, EDUARDO S.; SOUZA, CARLA D.; SOMESSARI, SAMIR L. Improvements in the quality control of iridium-192 wire used in brachytherapy. In: DUDALA, JOANNA (ed.); STEGOWSKI, ZDZISLAW (ed.). In: INTERNATIONAL CONFERENCE ON DEVELOPMENT AND APPLICATIONS OF NUCLEAR TECHNOLOGIES, September 11-14, 2011, Krakow, Poland. <b>Abstract...</b> Krakow, Poland: Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 2011. p. 126-126. Disponível em: http://repositorio.ipen.br/handle/123456789/33338.
dc.identifier.orcid0000-0003-2943-6097pt_BR
dc.identifier.orcid0000-0002-7303-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-5054-0799
dc.identifier.orcidhttp://orcid.org/0000-0003-1335-8864
dc.identifier.orcidhttps://orcid.org/0000-0003-1691-2314
dc.identifier.orcidhttps://orcid.org/0000-0003-2943-6097
dc.identifier.orcidhttps://orcid.org/0000-0002-7303-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/33338
dc.localKrakow, Polandpt_BR
dc.local.eventoKrakow, Polandpt_BR
dc.publisherFaculty of Physics and Applied Computer Science, AGH University of Science and Technologypt_BR
dc.rightsopenAccesspt_BR
dc.subjectbrachytherapy
dc.subjectexternal irradiation
dc.subjectiridium 192
dc.subjectquality control
dc.subjectsealed sources
dc.titleImprovements in the quality control of iridium-192 wire used in brachytherapypt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorJOÃO AUGUSTO MOURA
ipen.autorCARLA DARUICH DE SOUZA
ipen.autorSAMIR LUIZ SOMESSARI
ipen.autorEDUARDO SANTANA DE MOURA
ipen.autorANSELMO FEHER
ipen.autorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.autorCARLOS ALBERTO ZEITUNI
ipen.autorOSVALDO LUIZ DA COSTA
ipen.codigoautor6611
ipen.codigoautor7717
ipen.codigoautor558
ipen.codigoautor5860
ipen.codigoautor786
ipen.codigoautor7
ipen.codigoautor944
ipen.codigoautor669
ipen.contributor.ipenauthorJOÃO AUGUSTO MOURA
ipen.contributor.ipenauthorCARLA DARUICH DE SOUZA
ipen.contributor.ipenauthorSAMIR LUIZ SOMESSARI
ipen.contributor.ipenauthorEDUARDO SANTANA DE MOURA
ipen.contributor.ipenauthorANSELMO FEHER
ipen.contributor.ipenauthorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.contributor.ipenauthorCARLOS ALBERTO ZEITUNI
ipen.contributor.ipenauthorOSVALDO LUIZ DA COSTA
ipen.date.recebimento22-10
ipen.event.datapadronizada2011pt_BR
ipen.identifier.ipendoc26556pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication6a96a2fe-6eb6-488b-bd21-ac2b4e1335a3
relation.isAuthorOfPublication866434dc-2634-4567-8b4b-04e5ce06bf04
relation.isAuthorOfPublication914423c4-dade-4da4-9a50-05fdf3f7a878
relation.isAuthorOfPublicationfa668b29-92e1-43e8-b9db-5c151ab7d93d
relation.isAuthorOfPublication52268eaa-9747-4444-b301-7e33219b912c
relation.isAuthorOfPublicationda77b491-04ff-4c68-aa65-dead9208a48c
relation.isAuthorOfPublication02421b96-adef-4759-b25e-67d4759aa676
relation.isAuthorOfPublication61396bf8-f804-4323-a509-a1e70ffe4a3c
relation.isAuthorOfPublication.latestForDiscovery61396bf8-f804-4323-a509-a1e70ffe4a3c
sigepi.autor.atividadeSOMESSARI, SAMIR L.:558:240:Npt_BR
sigepi.autor.atividadeSOUZA, CARLA D.:7717:230:Npt_BR
sigepi.autor.atividadeMOURA, EDUARDO S.:5860:230:Npt_BR
sigepi.autor.atividadeFEHER, ANSELMO:786:230:Npt_BR
sigepi.autor.atividadeMOURA, JOÃO A.:6611:230:Npt_BR
sigepi.autor.atividadeROSTELATO, MARIA E.C.M.:7:230:Npt_BR
sigepi.autor.atividadeZEITUNI, CARLOS A.:944:230:Npt_BR
sigepi.autor.atividadeCOSTA, OSVALDO L.:669:230:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26556.pdf
Tamanho:
26.18 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: