A thermal investigation of dental bleaching in vitro

dc.contributor.authorKABBACH, WILLIAMpt_BR
dc.contributor.authorZEZELL, DENISE M.pt_BR
dc.contributor.authorPEREIRA, THIAGO M.pt_BR
dc.contributor.authorALBERO, FELIPE G.pt_BR
dc.contributor.authorCLAVIJO, VICTOR R.G.pt_BR
dc.contributor.authorANDRADE, MARCELO F. dept_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:43:15Zpt_BR
dc.date.accessioned2014-07-30T11:50:11Z
dc.date.available2014-07-15T13:43:15Zpt_BR
dc.date.available2014-07-30T11:50:11Z
dc.date.issued2008pt_BR
dc.description.abstractObjective: Our goal was to investigate the surface temperature variations in the cervical region via infrared thermography, as well as the temperature within the pulp chamber via thermocouples, of mandibular incisors when subjected to dental bleaching using two different 35% hydrogen peroxide gels, red (HP) and green (HPM), when activated by halogen light (HL) and LED light. Background Data: Temperatures increases of more than 5.5°C are considered to be potentially threatening to pulp vitality, while those higher than 10°C can result in periodontal injury. Materials and Methods: Tooth samples were randomly divided into four groups (n = 10 each), according to the bleaching agent and catalyst light source used. Results: Mean values and standard deviations of the temperature increases inside the pulp chamber in the HL groups were 4.4° ± 2.1°C with HP, and 4.5° ± 1.2°C with HPM; whereas in the groups using LED light, they were 1.4° ± 0.3°C for HP, and 1.5° ± 0.2°C for HPM. For the root surfaces, the maximum temperature increases in the groups irradiated with HL were 6.5° ± 1.5°C for HP, and 7.5° ± 1.1°C with HPM; whereas in the groups irradiated with LED light, they were 2.8° ± 0.7°C with HP, and 3° ± 0.8°C with HPM. There were no statistically significant differences in pulp and surface temperature increases between the groups using different gels, although the mean temperature increases were significantly higher for the groups irradiated with HL when compared with those irradiated with the LED light (p < 0.05 with Tukey's test). Conclusion: LED light may be safe for periodontal and pulp tissue when using this method, but HL should be used with care.
dc.format.extent489-493pt_BR
dc.identifier.citationKABBACH, WILLIAM; ZEZELL, DENISE M.; PEREIRA, THIAGO M.; ALBERO, FELIPE G.; CLAVIJO, VICTOR R.G.; ANDRADE, MARCELO F. de. A thermal investigation of dental bleaching in vitro. <b>Photomedicine and Laser Surgery</b>, v. 26, n. 5, p. 489-493, 2008. DOI: <a href="https://dx.doi.org/10.1089/pho.2007.2221">10.1089/pho.2007.2221</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5012.
dc.identifier.doi10.1089/pho.2007.2221
dc.identifier.fasciculo5pt_BR
dc.identifier.issn1549-5418pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7404-9606
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5012pt_BR
dc.identifier.vol26pt_BR
dc.relation.ispartofPhotomedicine and Laser Surgerypt_BR
dc.rightsopenAccessen
dc.subjectteethpt_BR
dc.subjectbleachingpt_BR
dc.subjectthermal analysispt_BR
dc.titleA thermal investigation of dental bleaching in vitropt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorFELIPE GUIMARÃES ALBERO
ipen.autorTHIAGO MARTINI PEREIRA
ipen.autorDENISE MARIA ZEZELL
ipen.codigoautor5888
ipen.codigoautor4003
ipen.codigoautor693
ipen.contributor.ipenauthorFELIPE GUIMARÃES ALBERO
ipen.contributor.ipenauthorTHIAGO MARTINI PEREIRA
ipen.contributor.ipenauthorDENISE MARIA ZEZELL
ipen.date.recebimento09-02pt_BR
ipen.identifier.fi1.785pt_BR
ipen.identifier.ipendoc13209pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.type.genreArtigo
relation.isAuthorOfPublicationddb121ad-7cdc-49be-b75c-5dec85d804e5
relation.isAuthorOfPublicationefbdbfff-da00-465c-8cf7-df3b125b8444
relation.isAuthorOfPublicationa565f8ad-3432-4891-98c0-a587f497db21
relation.isAuthorOfPublication.latestForDiscoverya565f8ad-3432-4891-98c0-a587f497db21
sigepi.autor.atividadeZEZELL, DENISE M.:693:920:Npt_BR
sigepi.autor.atividadePEREIRA, THIAGO M.:4003:920:Npt_BR
sigepi.autor.atividadeALBERO, FELIPE G.:5888:920:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13209.pdf
Tamanho:
109.26 KB
Formato:
Adobe Portable Document Format
Coleções