An extrapolation chamber for the establishment of a primary radiation standard in 85Kr and 147Pm beta radiation beams

dc.contributor.authorPOLO, IVON O.pt_BR
dc.contributor.authorSANTOS, WILLIAM S.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rdpt_BR
dc.date.accessioned2020-03-31T18:26:57Z
dc.date.available2020-03-31T18:26:57Z
dc.date.eventoMay 27-31, 2019pt_BR
dc.description.abstractIntroduction At the Calibration Laboratory (LCI) of the IPEN/CNEN, studies are in development on the establishment of the Böhm extrapolation chamber model 23392 as a primary standard system for the dosimetry and calibration of beta-radiation sources and detectors. This chamber was already characterized at the LCI in 90Sr/90Y beams using two different entrance windows: one of aluminized Mylar and another of Hostaphan. This extrapolation chamber was characterized in 85Kr and 147Pm beams. All tests were carried out with the reference 90Sr /90Y source, for comparative purposes. Methods A Keithley model 6517B electrometer was used for the measurements. The utilized radiation sources are part of the Beta Secondary Standard BSS2. Moreover, the Monte Carlo code MCNP5 was used to determine the absorbed dose rates and to compare them with the experimentally determined dose rates and with those from the PTB calibration certifi cate. Results Saturation curves, ion collection effi ciency, ion recombination, polarity effect, response stability, real null depth, linearity of response, variation of response as a function of sourcedetector distance, extrapolation curves, correction factors and absorbed dose rates were obtained. The ion collection effi ciency was greater than 99%; the ionic recombination was less than 1%, and the polarity effect was greater than 1%. The stability of the response was lower than 0.15% for the repeatability test, and it was less than 0.36% for the reproducibility test. The difference between the experimental absorbed dose rates and those from the Monte Carlo model, compared to those from the calibration certifi cate, was less than 1.9% for all sources. Conclusions All results of the performed tests are within the limits of the international recommendations. The results for the 90Sr/90Y source were in the good agreement with previous works performed at LCI. These results are suitable for the establishment of a primary standard for beta radiation.pt_BR
dc.event.siglaICDApt_BR
dc.identifier.citationPOLO, IVON O.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E. An extrapolation chamber for the establishment of a primary radiation standard in 85Kr and 147Pm beta radiation beams. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. <b>Abstract...</b> Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/31013.
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31013
dc.localLisboa, Portugalpt_BR
dc.local.eventoLisboa, Portugalpt_BR
dc.publisherC2TN, Instituto Superior Técnico, Universidade de Lisboapt_BR
dc.rightsopenAccesspt_BR
dc.titleAn extrapolation chamber for the establishment of a primary radiation standard in 85Kr and 147Pm beta radiation beamspt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorWILLIAM DE SOUZA SANTOS
ipen.autorLINDA V. E. CALDAS
ipen.autorIVON ORAMAS POLO
ipen.codigoautor12113
ipen.codigoautor1495
ipen.codigoautor14120
ipen.contributor.ipenauthorWILLIAM DE SOUZA SANTOS
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorIVON ORAMAS POLO
ipen.date.recebimento20-03
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26808pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicatione60e87cd-ba27-4148-a906-95e6cefff669
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication685f842c-100e-4c4e-ad40-d73c77cc2a75
relation.isAuthorOfPublication.latestForDiscovery685f842c-100e-4c4e-ad40-d73c77cc2a75
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeSANTOS, WILLIAM S.:12113:330:Npt_BR
sigepi.autor.atividadePOLO, IVON O.:14120:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26808.pdf
Tamanho:
202.39 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: