Application of a Tandem system for HVL evaluation in computed tomography

dc.contributor.authorFONTES, LADYJANE P.pt_BR
dc.contributor.authorCORREA, EDUARDO L.pt_BR
dc.contributor.authorPOTIENS, MARIA da P.A.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-07-25T18:26:52Z
dc.date.available2019-07-25T18:26:52Z
dc.date.issued2019pt_BR
dc.description.abstractComputed tomography (CT) is a method of imaging used for the diagnosis and treatment of diseases. Different from the conventional diagnostic radiology equipment, where the test for the determination of the half value layer (HVL) is recommended, in CT equipment due to its geometry, the determination of the HVL is a difficult task and is usually only provided by the manufacturer. The effective energy of a beam is determined by definition, by means of HVL determination. When HVL values are not easily determined, as in the case of CT, it is possible to evaluate the effective energy of the beam through a system consisting of the use of different energy dependent dosimeters, where the ratio between the calibration curve responses in energy can provide the effective energy of the beam (Tandem system). The system used in this work for the evaluation of HVL in computed tomography is composed of groups formed by an ionization chamber of the pencil-type and cylindrical absorber layers of aluminum and Polymethyl methacrylate (PMMA).pt_BR
dc.format.extent62-64pt_BR
dc.identifier.citationFONTES, LADYJANE P.; CORREA, EDUARDO L.; POTIENS, MARIA da P.A. Application of a Tandem system for HVL evaluation in computed tomography. <b>Radiation Physics and Chemistry</b>, v. 155, p. 62-64, 2019. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2018.08.023">10.1016/j.radphyschem.2018.08.023</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29953.
dc.identifier.doi10.1016/j.radphyschem.2018.08.023pt_BR
dc.identifier.issn0969-806Xpt_BR
dc.identifier.orcid0000-0002-4049-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfi60.153pt_BR
dc.identifier.percentilfiCiteScore73.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29953
dc.identifier.vol155pt_BR
dc.relation.ispartofRadiation Physics and Chemistrypt_BR
dc.rightsopenAccesspt_BR
dc.subjecttomography
dc.subjectcomputerized tomography
dc.subjectradiations
dc.subjectradiation chemistry
dc.subjectionization chambers
dc.subjectpmma
dc.titleApplication of a Tandem system for HVL evaluation in computed tomographypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorLADYJANE PEREIRA FONTES
ipen.codigoautor346
ipen.codigoautor7498
ipen.codigoautor12137
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorLADYJANE PEREIRA FONTES
ipen.date.recebimento19-07
ipen.identifier.fi2.226pt_BR
ipen.identifier.fiCiteScore3.7
ipen.identifier.ipendoc25736pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublication00349d21-f362-4498-a5c0-691c31365fa4
relation.isAuthorOfPublication.latestForDiscovery00349d21-f362-4498-a5c0-691c31365fa4
sigepi.autor.atividadePOTIENS, MARIA da P.A.:346:330:Npt_BR
sigepi.autor.atividadeCORREA, EDUARDO L.:7498:310:Npt_BR
sigepi.autor.atividadeFONTES, LADYJANE P.:12137:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25736.pdf
Tamanho:
444.24 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções