Ethylene-vinyl acetate detector exposed to gamma radiation and evaluated via principal component regression

dc.contributor.authorOLIVEIRA, L.N.pt_BR
dc.contributor.authorNASCIMENTO, E.O.pt_BR
dc.contributor.authorANTONIO, P.L.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoLATIN-AMERICAN CONGRESS ON SOLID STATE DOSIMETRY AND RADIATION MEASUREMENTS, 1stpt_BR
dc.date.accessioned2022-03-31T13:57:28Z
dc.date.available2022-03-31T13:57:28Z
dc.date.eventoSeptember 13-17, 2021pt_BR
dc.description.abstractIntroduction: Applications of ethylene-vinyl acetate (EVA) have been reported in radiation physics research, such as in electron beam irradiations, UV measurements and microwave irradiations. Gamma radiation is well known and presents several applications for radiation dosimetry [1]. The evaluation of EVA and other dosimeters can be undertaken by the Fourier Transform Infrared (FTIR) spectrophotometry technique. The goal of this work was to investigate the effect of gamma radiation in green, white and black EVA dosimeter samples for their sensitivity and linearity response, using the PCR method, and evaluated with the FTIR spectrophotometry technique. Material and method: The EVA samples had dimensions of 0.5 x 0.5 x 0.1 cm3, in colors green, white and black. These samples were irradiated in triplicates, with absorbed doses of 0.01 kGy, 0.05 kGy, 0.10 kGy, 0.25 kGy, 0.50 kGy, 1.0 kGy, 5.0 kGy and 10.0 kGy using a 60Co Gamma Cell-220 system (dose rate of 1.089 kGy/h of the Radiation Technology Center of IPEN); afterwards, the absorbance spectrum of each sample was acquired on a Fourier Transform Infrared (FTIR) spectrometer (Frontier/Perkin Elmer) from 400 cm-1 to 4000 cm-1, with 1 cm-1 spectral resolution. The linearity of response was evaluated using the Pearson correlation coefficient (R2). The sensitivity was set as the linear coefficient from a simple linear regression that was fitted using the Ordinary Least Squares Method between the absorbed doses and absorbance values for each wavenumber in the spectra for all colors of EVA samples. The PCR method combines all spectra from absorbance measurements into a single matrix, called here as Xnm, where n is the absorbed doses that varied discreetly from n = 1 up to 8, matching the absorbed doses of 0.01 kGy, 0.05 kGy, 0.10 kGy, 0.25 kGy, 0.50 kGy, 1.0 kGy, 5.0 kGy and 10.0 kGy, m is the spectral resolution index, from m = 1 up to 3600, equivalent to the range from 400 cm-1 to 4000 cm-1. Results: Predicted absorbed dose versus absorbed dose data are shown in Figure 1, for the PCR method, for EVA samples of all colors. The R2 obtained was 1.000 for the PCR method. It can be inferred that these methods are a good alternative, in the applications that require assessing linearity response in dosimetry, since the measurements from each kind of sample may be transformed in linear results. Consequently, these methods can be associated with other characteristics from radiation dosimetry as: reproducibility, fading, spatial resolution and others. Conclusion: EVA samples can be considered as a promising material for measurements of high doses of gamma radiation.pt_BR
dc.event.siglaLASSDpt_BR
dc.identifier.citationOLIVEIRA, L.N.; NASCIMENTO, E.O.; ANTONIO, P.L.; CALDAS, L.V.E. Ethylene-vinyl acetate detector exposed to gamma radiation and evaluated via principal component regression. In: LATIN-AMERICAN CONGRESS ON SOLID STATE DOSIMETRY AND RADIATION MEASUREMENTS, 1st, September 13-17, 2021, Online. <b>Resumo expandido...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/32923.
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32923
dc.local.eventoOnlinept_BR
dc.rightsopenAccesspt_BR
dc.subjectvinyl acetate
dc.subjectethylene
dc.subjectpolymerase chain reaction
dc.subjectelectron beams
dc.titleEthylene-vinyl acetate detector exposed to gamma radiation and evaluated via principal component regressionpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorPATRICIA DE LARA ANTONIO
ipen.autorLUCAS NONATO DE OLIVEIRA
ipen.codigoautor1495
ipen.codigoautor6585
ipen.codigoautor10632
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorPATRICIA DE LARA ANTONIO
ipen.contributor.ipenauthorLUCAS NONATO DE OLIVEIRA
ipen.date.recebimento22-03
ipen.event.datapadronizada2021pt_BR
ipen.identifier.ipendoc28637pt_BR
ipen.notas.internasResumo expandidopt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication5ea4ca8b-8415-4439-81d2-6fe0d6debd42
relation.isAuthorOfPublication87cc29f4-0e1f-4f7f-87ab-618b39834eb2
relation.isAuthorOfPublication.latestForDiscovery87cc29f4-0e1f-4f7f-87ab-618b39834eb2
sigepi.autor.atividadeCALDAS, L.V.E.:1495:330:Npt_BR
sigepi.autor.atividadeANTONIO, P.L.:6585:330:Npt_BR
sigepi.autor.atividadeOLIVEIRA, L.N.:10632:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
28637.pdf
Tamanho:
230.14 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: