Characteristics of electric double layer capacitors prepared with electrolytes based on deep eutectic solvents
Carregando...
Data
Data de publicação:
2022
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
É parte de
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 24.
Resumo
The storage capacity of electric double layer capacitors or electrochemical supercapacitors with
electrolytes based on deep eutectic solvents (DES) composed of L-lactic acid with several hydrogen
bond acceptors (nicotinamide, L-alanine, ammonium acetate, sodium acetate, choline chloride,
amino acetic acid) with a molar ratio of 7:1 have been investigated. A DES based on urea and
choline chloride with at a molar ration of 2:1 has also been included for comparison. The
electrochemical supercapacitors were prepared using commercial activated carbon electrodes after
removing the volatile organic electrolyte with a vacuum pump. The characteristics of the
electrochemical supercapacitors were determined by cyclic voltammetry at temperature room
temperature and also after heating at 353 K using scan rates that varied from 2 to 25 mVs-1.
Lowest scan rate led to higher specific capacitance of 150±8 Fg-1 with a maximum applied
potential of 1.7 V for the urea and choline chloride DES with a molar ration of 2:1. The lactic acid
with all the hydrogen bond acceptors with a molar ratio 7:1 it has been necessary to increase the
temperature above room temperature to improve the specific capacitance.
Como referenciar
GALDINO, G.S.; RODRIGUES, W.C.; CRUZ, P.D.; CASINI, J.S.; SAKATA, S.K.; FARIA, R.N. Characteristics of electric double layer capacitors prepared with electrolytes based on deep eutectic solvents. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 24., 6-10 de novembro, 2022, Águas de Lindóia, SP. Resumo... Disponível em: http://repositorio.ipen.br/handle/123456789/33835. Acesso em: 15 Mar 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.