Influence of BPL-based reconstruction algorithm on image quality for quantitative 90Y-PET imaging

dc.contributor.authorCARIBE, P.R.R.V.pt_BR
dc.contributor.authorBONIFACIO, D.A.B.pt_BR
dc.contributor.authorCORDEIRO, L.P.pt_BR
dc.contributor.authorSILVA, A.M.M. dapt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoLATIN-AMERICAN CONGRESS ON SOLID STATE DOSIMETRY AND RADIATION MEASUREMENTS, 1stpt_BR
dc.date.accessioned2022-03-31T14:15:32Z
dc.date.available2022-03-31T14:15:32Z
dc.date.eventoSeptember 13-17, 2021pt_BR
dc.description.abstractIntroduction: PET/CT technology and image reconstruction algorithms are constantly being improved. This leads to changes in the resulting images which need to be tested and clinically validated. This study evaluated the performance and clinical use of the Bayesian Penalized-Likelihood (BPL) reconstruction algorithm on the state-of-the-art SiPM-based PET/CT for quantitative 90Y-PET imaging. Method: An image quality (IQ) phantom with an 8:1 hot sphere-to-background ratio was scanned on a GE Discovery MI 3-rings PET/CT system during a single bed scan. 90Y acquisition time was 14h and 20 min (representative for clinical count statistics) for an activity concentration of 218 kBq/ml. Reconstructions were performed using: 3-iterations OSEM algorithm with 16 subsets and Gaussian post-filter FWHM ranging from 4.5 to 10 mm; BPL-based algorithm employing a block sequential regularized expectation maximization (BSREM) with Beta parameter varying from 300 to 3000. Time-of-flight and point-spread function modellings were included in all reconstructions. Contrast recovery (CR), background noise levels (coefficient of variation, COV), contrast-to-noise ratio (CNR) and metabolic tumour volume (MTV) were compared to investigate whether the BSREM reconstruction algorithm leads to an improvement in clinical image quality using 90Y. Results: The results for CR versus background COV of the IQ phantom are shown in Fig. 1. All plots show a similar trend: CRs values were as expected with higher CRs for lower β and post-filter FWHM values. The Contrast- to-noise ratio was significantly better in BSREM reconstructions when compared with OSEM in phantom studies. In terms of CR mapping, a BSREM β of 1000 corresponded to 5-6 mm post-filter for TOF-OSEM. Regarding noise characteristics of the 14h data, BSREM outperformed TOF-OSEM reconstructions in terms of noise levels with a 2-3 times lower background COV and improved SUVmean and MATV values for all spheres sizes. Lowering the counts for 20 min data, BSREM noise reduction can be controlled by increasing the β- parameter, but caution should be taken to avoid losing CR information. An optimal range of 1500-3000 β values, can provide a compromise between noise and CR at clinical count statistics. Conclusions: Based on a quantitative phantom study, the BPL-based reconstruction algorithm improves image quality and allows better noise characteristics for 90Y acquisitions when compared to OSEM reconstructions. BSREM reconstructions substantially improved contrast-to-noise ratio and MATVvalues for longer 90Y measurements with better count statistics. For clinically relevant count statistics, BSREM with β values lower than 500 had a limited impact on noise levels of 90Y-PET. The potential improvements of BPL applied to dosimetry calculations are currently being investigated to determine if BSREM can be used to avoids accuracy degradation in the absorbed dose distribution aiming at patient comfort.pt_BR
dc.event.siglaLASSDpt_BR
dc.identifier.citationCARIBE, P.R.R.V.; BONIFACIO, D.A.B.; CORDEIRO, L.P.; SILVA, A.M.M. da. Influence of BPL-based reconstruction algorithm on image quality for quantitative 90Y-PET imaging. In: LATIN-AMERICAN CONGRESS ON SOLID STATE DOSIMETRY AND RADIATION MEASUREMENTS, 1st, September 13-17, 2021, Online. <b>Resumo expandido...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/32925.
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32925
dc.local.eventoOnlinept_BR
dc.rightsopenAccesspt_BR
dc.subjectimages
dc.subjectpositron computed tomography
dc.subjectyttrium 90
dc.subjectalgorithms
dc.titleInfluence of BPL-based reconstruction algorithm on image quality for quantitative 90Y-PET imagingpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorDANIEL ALEXANDREBAPTISTA BONIFACIO
ipen.codigoautor3714
ipen.contributor.ipenauthorDANIEL ALEXANDREBAPTISTA BONIFACIO
ipen.date.recebimento22-03
ipen.event.datapadronizada2021pt_BR
ipen.identifier.ipendoc28639pt_BR
ipen.notas.internasResumo expandidopt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7a3a4adc-12d8-44a2-84ce-a362abe8d719
relation.isAuthorOfPublication.latestForDiscovery7a3a4adc-12d8-44a2-84ce-a362abe8d719
sigepi.autor.atividadeBONIFACIO, D.A.B.:3714:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
28639.pdf
Tamanho:
516.39 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: