The influence of erbium:yttrium-aluminium-garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations

Carregando...
Imagem de Miniatura

Data

Data de publicação

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

Lasers in Medical Science
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium–aluminum–garnet (Er:YAG) laser (2.94 μm) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n=6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37°C in distilled water, polished after 24 h, and thermally stressed (700 cycles/555°C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0–3). The results were analyzed by Kruskal–Wallis test (P>0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.

Como referenciar
NAVARRO, RICARDO S.; GOUW-SOARES, SHEILA; CASSONI, ALESSANDRA; HAYPEK, PATRICIA; ZEZELL, DENISE M.; EDUARDO, CARLOS de P. The influence of erbium:yttrium-aluminium-garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations. Lasers in Medical Science, v. 25, n. 6, p. 881-889, 2010. DOI: 10.1007/s10103-009-0736-6. Disponível em: http://repositorio.ipen.br/handle/123456789/8053. Acesso em: 20 Mar 2026.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento

Coleções