Image quality analysis of an industrial instant non-scanning tomography system with different collimators

dc.contributor.authorVELO, A.F.pt_BR
dc.contributor.authorALVAREZ, A.G.pt_BR
dc.contributor.authorHAMADA, M.M.pt_BR
dc.contributor.authorMESQUITA, C.H.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2019-07-31T17:18:00Z
dc.date.available2019-07-31T17:18:00Z
dc.date.issued2019pt_BR
dc.description.abstractAn instant non-scanning tomography system is being developed at the IPEN. This type of tomography system, due to its configurations, provides a low spatial resolution; however, it presents a high temporal resolution as an advantage. In this sense, it has high applicability in industrial processes involving dynamic multiphase processes, like distillation columns. Thereby, to obtain the best conditions of image acquisition, this tomography system comprising different collimators was simulated with Monte Carlo using the MCNP4C.The image quality was evaluated with Matlab® 2013b analyzing the contrast to noise ratio (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to identify which collimator fits better to the tomography in development. It was simulated three situations; (i) with no collimator; (ii) ø 25x 50 mm2 cylindrical collimator with a septum of ø5.0 x 50 mm2; (iii) ø25 x 50 mm2 cylindrical collimator with a slit septum of 24 x 5.0 x 50 mm3. RMSE values for no collimator presented better results. CNR showed that no collimator and slit collimator reaches the same CNR values, but no collimator decreases more than the slit collimator as the number of iteration rises. The hole collimator reaches a higher CNR value, however decreases more than the others. The spatial resolution with no collimator and slit collimator were around 31.9 mm, and for the hole collimator was around 20 mm.pt_BR
dc.format.extent1-14pt_BR
dc.identifier.citationVELO, A.F.; ALVAREZ, A.G.; HAMADA, M.M.; MESQUITA, C.H. Image quality analysis of an industrial instant non-scanning tomography system with different collimators. <b>Brazilian Journal of Radiation Sciences</b>, v. 7, n. 2A, p. 1-14, 2019. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v7i2A.561">10.15392/bjrs.v7i2A.561</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29991.
dc.identifier.doi10.15392/bjrs.v7i2A.561pt_BR
dc.identifier.fasciculo2Apt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcid0000-0002-6879-2468pt_BR
dc.identifier.orcid0000-0001-9786-4136pt_BR
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29991
dc.identifier.vol7pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceThe Meeting on Nuclear Applications (ENAN), 13th, 22-27 de outubro, 2017, Belo Horizonte, MGpt_BR
dc.subjectcollimators
dc.subjecttomography
dc.subjectcomputerized tomography
dc.subjectcomputerized simulation
dc.subjectmonte carlo method
dc.subjectquality assurance
dc.subjectquality management
dc.subjectimage processing
dc.subjectnai detectors
dc.subjectsignal-to-noise ratio
dc.subjectradiation detectors
dc.subjectradiation detectors
dc.subjectindustrial plants
dc.subjectbrazilian cnen
dc.titleImage quality analysis of an industrial instant non-scanning tomography system with different collimatorspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorCARLOS HENRIQUE DE MESQUITA
ipen.autorMARGARIDA MIZUE HAMADA
ipen.autorALEXANDRE GIMENEZ ALVAREZ
ipen.autorALEXANDRE FRANÇA VELO
ipen.codigoautor1149
ipen.codigoautor1476
ipen.codigoautor14665
ipen.codigoautor12736
ipen.contributor.ipenauthorCARLOS HENRIQUE DE MESQUITA
ipen.contributor.ipenauthorMARGARIDA MIZUE HAMADA
ipen.contributor.ipenauthorALEXANDRE GIMENEZ ALVAREZ
ipen.contributor.ipenauthorALEXANDRE FRANÇA VELO
ipen.date.recebimento19-07
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc25780pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication20d22e5e-a0d1-4286-b4d9-20e5ac53cb51
relation.isAuthorOfPublication74139eee-5dbd-4dfd-b672-89cb56c5cce5
relation.isAuthorOfPublicatione6fc5ff0-9297-486c-99e8-bf64ec2fc502
relation.isAuthorOfPublicationb295ccf7-5904-42e8-aa60-0d9fd45e1100
relation.isAuthorOfPublication.latestForDiscoveryb295ccf7-5904-42e8-aa60-0d9fd45e1100
sigepi.autor.atividadeMESQUITA, C.H.:1149:240:Npt_BR
sigepi.autor.atividadeHAMADA, M.M.:1476:240:Npt_BR
sigepi.autor.atividadeALVAREZ, A.G.:14665:240:Npt_BR
sigepi.autor.atividadeVELO, A.F.:12736:240:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25780.pdf
Tamanho:
441.3 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções