Portal dosimetry in wedged beams

dc.contributor.authorSPREEUW, HANNO
dc.contributor.authorROZENDAAL, ROEL
dc.contributor.authorCAMARGO, PRISCILLA
dc.contributor.authorMANS, ANTON
dc.contributor.authorWENDLING, MARKUS
dc.contributor.authorOLACIREGUI-RUIZ, IGOR
dc.contributor.authorSONKE, JAN J.
dc.contributor.authorHERK, MARCEL van
dc.contributor.authorMIJNHEER, BEN
dc.coverageInternacionalpt_BR
dc.date.accessioned2015-07-23T16:58:52Z
dc.date.available2015-07-23T16:58:52Z
dc.date.issued2015pt_BR
dc.description.abstractPortal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the situation without wedge is used. A possible solution would be to consider a wedged beam as another photon beam quality requiring separate beam modeling of the dose calculation algorithm. The aim of this study was to investigate a more practical solution: to make aSi EPID-based dosimetry models also applicable for wedged beams without an extra commissioning effort of the parameters of the model. For this purpose two energy-dependent wedge multiplication factors have been introduced to be applied for portal images taken with and without a patient/phantom in the beam. These wedge multiplication factors were derived from EPID and ionization chamber measurements at the EPID level for wedged and nonwedged beams, both with and without a polystyrene slab phantom in the beam. This method was verified for an EPID dosimetry model used for wedged beams at three photon beam energies (6, 10, and 18 MV) by comparing dose values reconstructed in a phantom with data provided by a treatment planning system (TPS), as a function of field size, depth, and off-axis distance. Generally good agreement, within 2%, was observed for depths between dose maximum and 15 cm. Applying the new model to EPID dose measurements performed during ten breast cancer patient treatments with wedged 6 MV photon beams showed that the average isocenter underdosage of 5.3% was reduced to 0.4%. Gamma-evaluation (global 3%/3 mm) of these in vivo data showed an increase in percentage of points with γ ≤ 1 from 60.2% to 87.4%, while γmean reduced from 1.01 to 0.55. It can be concluded that, for wedged beams, the multiplication of EPID pixel values with an energy-dependent correction factor provides good agreement between dose values determined by an EPID and a TPS, indicating the usefulness of such a practical solution.
dc.format.extent244-257pt_BR
dc.identifier.citationSPREEUW, HANNO; ROZENDAAL, ROEL; CAMARGO, PRISCILLA; MANS, ANTON; WENDLING, MARKUS; OLACIREGUI-RUIZ, IGOR; SONKE, JAN J.; HERK, MARCEL van; MIJNHEER, BEN. Portal dosimetry in wedged beams. <b>Journal of Applied Clinical Medical Physics</b>, v. 16, n. 3, p. 244-257, 2015. DOI: <a href="https://dx.doi.org/10.1120/jacmp.v16i3.5375">10.1120/jacmp.v16i3.5375</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/23857.
dc.identifier.doi10.1120/jacmp.v16i3.5375
dc.identifier.fasciculo3pt_BR
dc.identifier.issn1526-9914pt_BR
dc.identifier.percentilfi29.44
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/23857
dc.identifier.vol16pt_BR
dc.relation.ispartofJournal of Applied Clinical Medical Physicspt_BR
dc.rightsopenAccesspt_BR
dc.subjectdosimetry
dc.subjectphoton beams
dc.subjecttherapy
dc.titlePortal dosimetry in wedged beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorPRISCILLA ALVES DE CAMARGO
ipen.codigoautor3010
ipen.contributor.ipenauthorPRISCILLA ALVES DE CAMARGO
ipen.date.recebimento15-07pt_BR
ipen.identifier.fi1.444pt_BR
ipen.identifier.ipendoc20893pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.identifier.ods3
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublication73808364-f7d0-463f-bc9d-6b79e1b0c443
relation.isAuthorOfPublication.latestForDiscovery73808364-f7d0-463f-bc9d-6b79e1b0c443
sigepi.autor.atividadeCAMARGO, PRISCILLA:3010:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
20893.pdf
Tamanho:
924.02 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções