Development of an industrial computed to mography designed with a plastic scintillator position sensitive detector
Carregando...
Data
Data de publicação
2005
Autores IPEN
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
É parte de
NUCLEAR SCIENCE SYMPOSIUM/MEDICAL IMAGING CONFERENCE
Resumo
An industrial computed tomography (CT) using
the plastic scintillator (PS) as a detector sensitive to the
radiation interaction position was proposed. Firstly, a code
using Monte Carlo method was developed to study the effects
of the plastic scintillator geometry in its gamma ray detection.
The software simulates the results system designed with two
photomultiplier-tubes set up in coincidence. Four simulations
sets were performed to foresee the effect of the diameter (5-
50cm) and length (1-128cm) of the detectors. The plastic
scintillator was designed to be used for the industrial
tomography system application. The Monte Carlo developed
code was validated for its use to foresee the suitable
dimension of the scintillator detector and some geometrical
aspects.
Como referenciar
MESQUITA, CARLOS H. de; LEGOUPIL, SAMUEL; HAMADA, MARGARIDA M. Development of an industrial computed to mography designed with a plastic scintillator position sensitive detector. In: NUCLEAR SCIENCE SYMPOSIUM/MEDICAL IMAGING CONFERENCE, October 23-29, 2005, Fajardo, PR. Proceedings... p. 540-544. DOI: 10.1109/NSSMIC.2005.1596310. Disponível em: http://repositorio.ipen.br/handle/123456789/16070. Acesso em: 20 Mar 2026.