Development of an industrial computed to mography designed with a plastic scintillator position sensitive detector
| dc.contributor.author | MESQUITA, CARLOS H. de | pt_BR |
| dc.contributor.author | LEGOUPIL, SAMUEL | pt_BR |
| dc.contributor.author | HAMADA, MARGARIDA M. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | NUCLEAR SCIENCE SYMPOSIUM/MEDICAL IMAGING CONFERENCE | pt_BR |
| dc.date.accessioned | 2014-11-17T18:05:02Z | pt_BR |
| dc.date.accessioned | 2014-11-18T18:18:47Z | pt_BR |
| dc.date.accessioned | 2015-04-01T23:39:23Z | |
| dc.date.available | 2014-11-17T18:05:02Z | pt_BR |
| dc.date.available | 2014-11-18T18:18:47Z | pt_BR |
| dc.date.available | 2015-04-01T23:39:23Z | |
| dc.date.evento | October 23-29, 2005 | pt_BR |
| dc.description.abstract | An industrial computed tomography (CT) using the plastic scintillator (PS) as a detector sensitive to the radiation interaction position was proposed. Firstly, a code using Monte Carlo method was developed to study the effects of the plastic scintillator geometry in its gamma ray detection. The software simulates the results system designed with two photomultiplier-tubes set up in coincidence. Four simulations sets were performed to foresee the effect of the diameter (5- 50cm) and length (1-128cm) of the detectors. The plastic scintillator was designed to be used for the industrial tomography system application. The Monte Carlo developed code was validated for its use to foresee the suitable dimension of the scintillator detector and some geometrical aspects. | |
| dc.event.sigla | NSS/MIC | pt_BR |
| dc.format.extent | 540-544 | pt_BR |
| dc.identifier.citation | MESQUITA, CARLOS H. de; LEGOUPIL, SAMUEL; HAMADA, MARGARIDA M. Development of an industrial computed to mography designed with a plastic scintillator position sensitive detector. In: NUCLEAR SCIENCE SYMPOSIUM/MEDICAL IMAGING CONFERENCE, October 23-29, 2005, Fajardo, PR. <b>Proceedings...</b> p. 540-544. DOI: <a href="https://dx.doi.org/10.1109/NSSMIC.2005.1596310">10.1109/NSSMIC.2005.1596310</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/16070. | |
| dc.identifier.doi | 10.1109/NSSMIC.2005.1596310 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/16070 | pt_BR |
| dc.local.evento | Fajardo, PR | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | computerized tomography | pt_BR |
| dc.subject | plastic scintillation detectors | pt_BR |
| dc.subject | monte carlo method | pt_BR |
| dc.subject | gamma radiation | pt_BR |
| dc.title | Development of an industrial computed to mography designed with a plastic scintillator position sensitive detector | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARGARIDA MIZUE HAMADA | |
| ipen.autor | CARLOS HENRIQUE DE MESQUITA | |
| ipen.codigoautor | 1476 | |
| ipen.codigoautor | 1149 | |
| ipen.contributor.ipenauthor | MARGARIDA MIZUE HAMADA | |
| ipen.contributor.ipenauthor | CARLOS HENRIQUE DE MESQUITA | |
| ipen.date.recebimento | 11-08 | pt_BR |
| ipen.event.datapadronizada | 2005 | pt_BR |
| ipen.identifier.ipendoc | 16782 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 74139eee-5dbd-4dfd-b672-89cb56c5cce5 | |
| relation.isAuthorOfPublication | 20d22e5e-a0d1-4286-b4d9-20e5ac53cb51 | |
| relation.isAuthorOfPublication.latestForDiscovery | 20d22e5e-a0d1-4286-b4d9-20e5ac53cb51 | |
| sigepi.autor.atividade | MESQUITA, CARLOS H. DE:1149:5:S | pt_BR |
| sigepi.autor.atividade | HAMADA, MARGARIDA M.:1476:5:N | pt_BR |
Pacote Original
1 - 1 de 1