dc.description.abstractSpectra of calibration sources and X-ray beams were measured with a cadmium telluride (CdTe) detector. The response function of the detector was simulated using the GEANT4 Monte Carlo toolkit. Trapping of charge carriers were taken into account using the Hecht equation in the active zone of the CdTe crystal associated with a continuous function to produce drop of charge collection efficiency near the metallic contacts and borders. The rise time discrimination is approximated by a cut in the depth of the interaction relative to cathode and corrections that depend on the pulse amplitude. The least-squares method with truncation was employed to unfold X-ray spectra typically used in medical diagnostics and the results were compared with reference data.
dc.format.extent270-273pt_BR
dc.identifier.citationMORALLES, M.; BONIFACIO, D.A.B.; BOTTARO, M.; PEREIRA, M.A.G. Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors. <b>Nuclear Instruments and Methods in Physics Research</b>, v. 580, p. 270-273, 2007. Section A. DOI: <a href="https://dx.doi.org/10.1016/j.nima.2007.05.147">10.1016/j.nima.2007.05.147</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5163.
dc.identifier.doi10.1016/j.nima.2007.05.147
dc.identifier.issn0168-9002pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-2664-5531
dc.identifier.suplementoSection Apt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5163pt_BR
dc.identifier.vol580pt_BR
dc.relation.ispartofNuclear Instruments and Methods in Physics Researchpt_BR
dc.rightsopenAccessen
dc.subjectx-ray spectrapt_BR
dc.subjectcdte semiconductor detectorspt_BR
dc.subjectmonte carlo methodpt_BR
dc.subjectleast square fitpt_BR
dc.subjectsimulationpt_BR
dc.subjectdiagnosispt_BR
dc.titleMonte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectorspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorDANIEL ALEXANDREBAPTISTA BONIFACIO
ipen.autorMAURICIO MORALLES
ipen.codigoautor3714
ipen.codigoautor923
ipen.contributor.ipenauthorDANIEL ALEXANDREBAPTISTA BONIFACIO
ipen.contributor.ipenauthorMAURICIO MORALLES
ipen.date.recebimento08-07pt_BR
ipen.identifier.fi1.114pt_BR
ipen.identifier.ipendoc12735pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication7a3a4adc-12d8-44a2-84ce-a362abe8d719
relation.isAuthorOfPublicationdc9e7d8e-c880-41f7-971e-b300272b6750
relation.isAuthorOfPublication.latestForDiscoverydc9e7d8e-c880-41f7-971e-b300272b6750
sigepi.autor.atividadeMORALLES, M.:923:6:Spt_BR
sigepi.autor.atividadeBONIFACIO, D.A.B.:3714:-1:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
12735.pdf
Tamanho:
340.95 KB
Formato:
Adobe Portable Document Format

Coleções