Monte Carlo studies on water and LiF cavity properties for dose-reporting quantities when using x-ray and brachytherapy sources

dc.contributor.authorBRANCO, ISABELA S.L.
dc.contributor.authorANTUNES, PAULA C.G.
dc.contributor.authorFONSECA, GABRIEL P.
dc.contributor.authorYORIYAZ, HELIO
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-01-18T10:39:23Z
dc.date.available2017-01-18T10:39:23Z
dc.date.issued2016pt_BR
dc.description.abstractModel-based dose calculation algorithms (MBDCAs) are the current tools to estimate dose in brachytherapy, which takes into account heterogeneous medium, therefore, departing from water-based formalism (TG-43). One aspect associated to MBCDA is the choice of dose specification medium since it offers two possibilities to report dose: (a) dose to medium in medium, D-m,D-m; and (b) dose to water in medium, D-w,D-m. The discussion about the preferable quantity to be reported is underway. The dose conversion factors, DCF, between dose to water in medium, D-w,D-m, and dose to medium in medium, D-m,D-m, is based on cavity theory and can be obtained using different approaches. When experimental dose verification is desired using, for example, thermoluminescent LiF dosimeters, as in in vivo dose measurements, a third quantity is obtained, which is the dose to LiF in medium, D-LiF,D-m. In this case, DCF to convert from D-LiF,D-m to Dw, m or Dm, m is necessary. The objective of this study is to estimate DCFs using different approaches, present in the literature, quantifying the differences between them. Also, dose in water and LiF cavities in different tissue media and respective conversion factors to be able to convert LiF-based dose measured values into dose in water or tissue were obtained. Simple cylindrical phantoms composed by different tissue equivalent materials (bone, lung, water and adipose) are modelled. The phantoms contain a radiation source and a cavity with 0.002 69 cm(3) in size, which is a typical volume of a disc type LiF dosimeter. Three x-rays qualities with average energies ranging from 47 to 250 keV, and three brachytherapy sources, Co-60, Ir-192 and Cs-137, are considered. Different cavity theory approaches for DCF calculations and different cavity/medium combinations have been considered in this study. DCF values for water/bone and LiF/bone cases have strong dependence with energy increasing as the photon energy increases. DCF values also increase with energy for LiF/lung and water/lung cases but, they are much less dependent of energy. For LiF/adipose, water/adipose and LiF/water cases, the DCF values are also dependent of photon energy but, decreases as the energy increases. Maximum difference of 12% has been found compared to values in literature.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipID305924/2013-3pt_BR
dc.format.extent8890-8907pt_BR
dc.identifier.citationBRANCO, ISABELA S.L.; ANTUNES, PAULA C.G.; FONSECA, GABRIEL P.; YORIYAZ, HELIO. Monte Carlo studies on water and LiF cavity properties for dose-reporting quantities when using x-ray and brachytherapy sources. <b>Physics in Medicine & Biology</b>, v. 61, p. 8890-8907, 2016. DOI: <a href="https://dx.doi.org/10.1088/1361-6560/61/24/8890">10.1088/1361-6560/61/24/8890</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/26989.
dc.identifier.doi10.1088/1361-6560/61/24/8890pt_BR
dc.identifier.issn22821pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.percentilfi71.55
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/26989
dc.identifier.vol61pt_BR
dc.relation.ispartofPhysics in Medicine & Biologypt_BR
dc.rightsopenAccesspt_BR
dc.subjectmonte carlo method
dc.subjectwater
dc.subjectlithium fluorides
dc.subjectx-ray sources
dc.subjectbrachytherapy
dc.subjectdoses
dc.subjectcomparative evaluations
dc.subjectskeleton
dc.subjectlungs
dc.subjectadipose tissue
dc.subjectphantoms
dc.subjectcobalt 60
dc.subjectiridium 192
dc.subjectcesium 137
dc.titleMonte Carlo studies on water and LiF cavity properties for dose-reporting quantities when using x-ray and brachytherapy sourcespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorHELIO YORIYAZ
ipen.autorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.autorISABELA SOARES LOPES BRANCO
ipen.codigoautor80
ipen.codigoautor5958
ipen.codigoautor12693
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.contributor.ipenauthorPAULA CRISTINA GUIMARÃES ANTUNES
ipen.contributor.ipenauthorISABELA SOARES LOPES BRANCO
ipen.date.recebimento17-01pt_BR
ipen.identifier.fi2.742pt_BR
ipen.identifier.ipendoc22821pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication6011fbed-3deb-4798-8497-135bee30261a
relation.isAuthorOfPublicationec6e0563-9502-4387-b367-af02340ab996
relation.isAuthorOfPublication.latestForDiscoveryec6e0563-9502-4387-b367-af02340ab996
sigepi.autor.atividadeBRANCO, ISABELA S.L.:12693:420:Spt_BR
sigepi.autor.atividadeANTUNES, PAULA C.G.:5958:420:Npt_BR
sigepi.autor.atividadeYORIYAZ, HELIO:80:420:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
22821.pdf
Tamanho:
1.63 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções