TL and OSL response of CaF2:Tm for electron beam radiation processing
Carregando...
Data
Data de publicação
2018
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
É parte de
INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th
Resumo
The use of electron beams for industrial applications has increased worldwide requiring
accurate dosimetry systems to assure the quality of irradiated products. The radiochromic
films and alanine/EPR dosimeters are often employed in electron beam radiation processing.
The thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters are
mainly used for the electron beam dosimetry for radiotherapy applications. The aim of this
work is to study the TL and infrared stimulated luminescence (IRSL) response of the calcium
fluoride dosimeter doped with thulium (CaF2:Tm) for electron beam radiation processing.
The pellets of CaF2:Tm (6mm in diameter and 1mm thickness) were produced via the solution
combustion synthesis technique at the Nuclear Energy Department - UFPE. The individual
TL and OSL sensitivities of a bach of these dosimeters were previously evaluated and 50
pellets with a standard deviation of 6% were selected to be used in this study. Irradiation was
performed at the Radiation Technology Center at IPEN-CNEN/SP using 1.5MeV electron
beam from a DC 1500/25/4 – JOB 188 accelerator covering the dose rate range 2-32kGy/s
and doses from 0.5kGy up to 10kGy. The TL and OSL readings were carried out after a
preheating at 100°C during 15min using a Riso TL/OSL reader, model DA-20. The TL
measurements were taken with a heating rate of 2°C/s, in the range from 50°C to 350°C. The
OSL readings were carried out with infrared stimulation with optical power attenuated to 20%
during 240s. Residual thermoluminescent glow curves for IRSL were recorded after
stimulation times. The reproducibility and stability of the TL and IRSL responses were also
evaluated, as well as the dependence with different dose rates from 2kGy/s up to 32kGy/s.
The results showed a deconvoluted TL glow curve with four components, being the main two
TL peaks centred in the regions of 150°C and 200°C. The area of the TL peaks increases
linearly with the absorbed dose up to 6kGy for all the dose rates evaluated. For doses higher
than 6kGy, the TL response is sublinear with saturation around 10kGy. The IRSL curves of
the dosimeters present a fast and a slow decaying IRSL signals. The total area of IRSL curves
were measured for both different doses and dose rates. The correspondent results were
linearly dependent on the absorbed dose and saturated in almost 10kGy. The IRSL residual
TL glow curves exhibited a symmetrical decrease to the growing OSL signal.
All the results presented regarding TL and IRSL response of CaF2:Tm have shown that these
dosimeters are suitable for electron beam dosimetry in radiation processing.
Como referenciar
ASFORA, VIVIANE K.; ANTONIO, PATRICIA L.; GONÇALVES, JOSEMARY A.C.; BARROS, VINICIUS S.M. de; BUENO, CARMEN C.; KHOURY, HELEN J.; CALDAS, LINDA V.E. TL and OSL response of CaF2:Tm for electron beam radiation processing. In: RUBIO, MARCELO (ed.); TIRAO, GERMAN (ed.). In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th, October 7-11, 2018, Córdoba, Argentina. Abstract... Córdoba: Centro de Excelencia en Productos y Procesos, 2018. p. 303-303. Disponível em: http://repositorio.ipen.br/handle/123456789/29751. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.