Effect of primer before resin cement on bracket base and the influence of storage time on shear bond strength
| dc.contributor.author | MOREIRA, FERNANDO C. | |
| dc.contributor.author | JACOB, HELDER B. | |
| dc.coverage | Internacional | |
| dc.date.accessioned | 2024-06-17T12:45:55Z | |
| dc.date.available | 2024-06-17T12:45:55Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | Background: The elapsed time after bracket bonding and sandblasting the base could influence the shear bond strength (SBS) to enamel. Aim: This study evaluated the effect of primer application on the bracket base before application of resin and its interaction with storage time and sandblasting factors on SBS. Materials and Methods: Brackets were bonded on the enamel surface of 160 bovine incisors divided into eight groups (n = 20) with mesh bases, with and without sandblasting, with different storage times (immediately and 24 h), and with two different techniques (with and without primer on the base before resin). Results: SBS mean in conventional and primer groups ranged from 23 ± 7.76 MPa to 48 ± 11.34 MPa, respectively. After 24 h period, SBS increased when the primer was applied before resin on the bracket bases (P < 0.001). The effect of each isolated factor (storage time and primer application) was statistically significant (P < 0.001). Primer application versus time factors was statistically significant (P < 0.001). Sandblasted bases were not influential on SBS separately or by any of the interaction factors (P = 0.628). Adhesive interface failures were significant when the adhesive remnant index was evaluated regarding storage time without primer (P = 0.022); however, primer application did not show significance when the time was evaluated (P = 0.686). Conclusion: Primer increases the SBS after a 24 h period. Most of the failures occurred at the enamel/adhesive interface. Sandblasting treatment of bracket bases did not influence the SBS. | |
| dc.format.extent | 32-40 | |
| dc.identifier.citation | MOREIRA, FERNANDO C.; JACOB, HELDER B. Effect of primer before resin cement on bracket base and the influence of storage time on shear bond strength. <b>Journal of Interdisciplinary Dentistry</b>, v. 14, n. 1, p. 32-40, 2024. DOI: <a href="https://dx.doi.org/10.4103/jid.jid_52_23">10.4103/jid.jid_52_23</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/48113. | |
| dc.identifier.doi | 10.4103/jid.jid_52_23 | |
| dc.identifier.fasciculo | 1 | |
| dc.identifier.issn | 2229-5194 | |
| dc.identifier.percentilfi | Sem Percentil | |
| dc.identifier.percentilfiCiteScore | Sem Percentil CiteScore | |
| dc.identifier.uri | https://repositorio.ipen.br/handle/123456789/48113 | |
| dc.identifier.vol | 14 | |
| dc.relation.ispartof | Journal of Interdisciplinary Dentistry | |
| dc.rights | openAccess | |
| dc.subject | composite materials | |
| dc.subject | resins | |
| dc.subject | shear properties | |
| dc.subject | teeth | |
| dc.subject | dentistry | |
| dc.title | Effect of primer before resin cement on bracket base and the influence of storage time on shear bond strength | |
| dc.type | Artigo de periódico | |
| dspace.entity.type | Publication | |
| ipen.autor | MOREIRA, FERNANDO C. | |
| ipen.identifier.fi | Sem F.I. | |
| ipen.identifier.fiCiteScore | Sem CiteScore | |
| ipen.identifier.ipendoc | 30421 | |
| ipen.type.genre | Artigo |