Neutron activation analysis technique, using Au as flux monitor, was applied to determine element concentrations of Ca, K, Na, Mg, Mn and Sr in certified reference material (NIST 1400 Bone Ash). The results were compared with those using comparative INAA and they were compatible. The same results were obtained using the recommended k0 factors, in order to obtain the activation cross section as input in concentration for the same reference material. Some applications in the health area aiming clinical evaluation in bone samples of medium and small-sized animals were performed and the viability of using this methodology was discussed.
Como referenciar
ZAMBONI, C.B.; OLIVEIRA, L.C.; DALAQUA JUNIOR, L.; MESA, J. Application of neutron activation analysis to bone samples. Journal of Radioanalytical and Nuclear Chemistry, v. 269, n. 2, p. p. 331-334, 2006. DOI: 10.1007/s10967-006-0387-z. Disponível em: http://repositorio.ipen.br/handle/123456789/5380. Acesso em: 30 Dec 2025.