Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications

dc.contributor.authorGONCALVES, J.A.C.pt_BR
dc.contributor.authorBUENO, C.C.pt_BR
dc.contributor.authorMANGIAROTTI, A.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2021-08-02T18:34:14Z
dc.date.available2021-08-02T18:34:14Z
dc.date.issued2021pt_BR
dc.description.abstractIn this work, we report a comparison between the performance of two samples of commercial PIN photodiodes (SFH206K from Osram® and S2506-04 from Hamamatsu®) mainly addressing the variation of their current sensitivities with accumulated dose ranging from 0-15 kGy. All the results so far obtained have revealed that the radiation induced currents are linearly dependent on dose rates from 3.65 to 55.64 Gy/h. The current sensitivity of both unirradiated diodes (0.178 nA.h/Gy.mm3) slightly decreases with accumulated dose, namely 0.32%/kGy (SFH206K) and 1.4%/kGy (S2506-04). Although the SFH206K device compares favorably with the S2506-04, both diodes can be considered as a low budge alternative, good enough for on-line dosimetry applications in the field of radiation processing.pt_BR
dc.description.sponsorshipInstituto de Pesquisas Energéticas e Nucleares (IPEN)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDIPEN-CNEN: DPDE 04/2017pt_BR
dc.description.sponsorshipIDCNPq: 306331/2016-0pt_BR
dc.format.extent1-8pt_BR
dc.identifier.citationGONCALVES, J.A.C.; BUENO, C.C.; MANGIAROTTI, A. Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications. <b>Brazilian Journal of Radiation Sciences</b>, v. 9, n. 1A, p. 1-8, 2021. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v9i1A.1327">10.15392/bjrs.v9i1A.1327</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32093.
dc.identifier.doi10.15392/bjrs.v9i1A.1327pt_BR
dc.identifier.fasciculo1Apt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7881-7254
dc.identifier.orcidhttps://orcid.org/0000-0002-8940-9544
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32093
dc.identifier.vol9pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceMeeting on Nuclear Applications (ENAN), 14th, October 21-25, 2019, Santos, SPpt_BR
dc.subjectcobalt 60
dc.subjectcomparative evaluations
dc.subjectdose rates
dc.subjectdosemeters
dc.subjectdosimetry
dc.subjectgamma radiation
dc.subjectperformance
dc.subjectphotodiodes
dc.subjectsensitivity
dc.titleComparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applicationspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorCARMEN CECILIA BUENO TOBIAS
ipen.autorJOSEMARY ANGELICA CORREA GONCALVES
ipen.codigoautor1592
ipen.codigoautor924
ipen.contributor.ipenauthorCARMEN CECILIA BUENO TOBIAS
ipen.contributor.ipenauthorJOSEMARY ANGELICA CORREA GONCALVES
ipen.date.recebimento21-08
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc27864pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationfa74399b-83a0-4f46-91e0-da469104d3f6
relation.isAuthorOfPublication76fdc4d1-7624-4332-a9d0-f06826000679
relation.isAuthorOfPublication.latestForDiscovery76fdc4d1-7624-4332-a9d0-f06826000679
sigepi.autor.atividadeBUENO, C.C.:1592:240:Npt_BR
sigepi.autor.atividadeGONCALVES, J.A.C.:924:240:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27864.pdf
Tamanho:
651.15 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções