Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications
| dc.contributor.author | GONCALVES, J.A.C. | pt_BR |
| dc.contributor.author | BUENO, C.C. | pt_BR |
| dc.contributor.author | MANGIAROTTI, A. | pt_BR |
| dc.coverage | Nacional | pt_BR |
| dc.date.accessioned | 2021-08-02T18:34:14Z | |
| dc.date.available | 2021-08-02T18:34:14Z | |
| dc.date.issued | 2021 | pt_BR |
| dc.description.abstract | In this work, we report a comparison between the performance of two samples of commercial PIN photodiodes (SFH206K from Osram® and S2506-04 from Hamamatsu®) mainly addressing the variation of their current sensitivities with accumulated dose ranging from 0-15 kGy. All the results so far obtained have revealed that the radiation induced currents are linearly dependent on dose rates from 3.65 to 55.64 Gy/h. The current sensitivity of both unirradiated diodes (0.178 nA.h/Gy.mm3) slightly decreases with accumulated dose, namely 0.32%/kGy (SFH206K) and 1.4%/kGy (S2506-04). Although the SFH206K device compares favorably with the S2506-04, both diodes can be considered as a low budge alternative, good enough for on-line dosimetry applications in the field of radiation processing. | pt_BR |
| dc.description.sponsorship | Instituto de Pesquisas Energéticas e Nucleares (IPEN) | pt_BR |
| dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | pt_BR |
| dc.description.sponsorshipID | IPEN-CNEN: DPDE 04/2017 | pt_BR |
| dc.description.sponsorshipID | CNPq: 306331/2016-0 | pt_BR |
| dc.format.extent | 1-8 | pt_BR |
| dc.identifier.citation | GONCALVES, J.A.C.; BUENO, C.C.; MANGIAROTTI, A. Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications. <b>Brazilian Journal of Radiation Sciences</b>, v. 9, n. 1A, p. 1-8, 2021. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v9i1A.1327">10.15392/bjrs.v9i1A.1327</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32093. | |
| dc.identifier.doi | 10.15392/bjrs.v9i1A.1327 | pt_BR |
| dc.identifier.fasciculo | 1A | pt_BR |
| dc.identifier.issn | 2319-0612 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0001-7881-7254 | |
| dc.identifier.orcid | https://orcid.org/0000-0002-8940-9544 | |
| dc.identifier.percentilfi | Sem Percentil | pt_BR |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/32093 | |
| dc.identifier.vol | 9 | pt_BR |
| dc.relation.ispartof | Brazilian Journal of Radiation Sciences | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | Meeting on Nuclear Applications (ENAN), 14th, October 21-25, 2019, Santos, SP | pt_BR |
| dc.subject | cobalt 60 | |
| dc.subject | comparative evaluations | |
| dc.subject | dose rates | |
| dc.subject | dosemeters | |
| dc.subject | dosimetry | |
| dc.subject | gamma radiation | |
| dc.subject | performance | |
| dc.subject | photodiodes | |
| dc.subject | sensitivity | |
| dc.title | Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | CARMEN CECILIA BUENO TOBIAS | |
| ipen.autor | JOSEMARY ANGELICA CORREA GONCALVES | |
| ipen.codigoautor | 1592 | |
| ipen.codigoautor | 924 | |
| ipen.contributor.ipenauthor | CARMEN CECILIA BUENO TOBIAS | |
| ipen.contributor.ipenauthor | JOSEMARY ANGELICA CORREA GONCALVES | |
| ipen.date.recebimento | 21-08 | |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 27864 | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | fa74399b-83a0-4f46-91e0-da469104d3f6 | |
| relation.isAuthorOfPublication | 76fdc4d1-7624-4332-a9d0-f06826000679 | |
| relation.isAuthorOfPublication.latestForDiscovery | 76fdc4d1-7624-4332-a9d0-f06826000679 | |
| sigepi.autor.atividade | BUENO, C.C.:1592:240:N | pt_BR |
| sigepi.autor.atividade | GONCALVES, J.A.C.:924:240:S | pt_BR |