Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams

dc.contributor.authorVENEZIANI, G.R.
dc.contributor.authorCORREA, E.L.
dc.contributor.authorPOTIENS, M.P.A.
dc.contributor.authorCAMPOS, L.L.
dc.coverageInternacionalpt_BR
dc.date.accessioned2017-09-28T11:16:46Z
dc.date.available2017-09-28T11:16:46Z
dc.date.issued2016pt_BR
dc.description.abstractIAEA code of practice TRS-457 states that standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine the attenuation coefficient of printed ABS and PLA samples in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.pt_BR
dc.format.extent1-6pt_BR
dc.identifier.citationVENEZIANI, G.R.; CORREA, E.L.; POTIENS, M.P.A.; CAMPOS, L.L. Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams. <b>Journal of Physics: Conference Series</b>, v. 733, p. 1-6, 2016. DOI: <a href="https://dx.doi.org/10.1088/1742-6596/733/1/012088">10.1088/1742-6596/733/1/012088</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/27807.
dc.identifier.doi10.1088/1742-6596/733/1/012088pt_BR
dc.identifier.issn1742-6588pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27807
dc.identifier.vol733pt_BR
dc.relation.ispartofJournal of Physics: Conference Seriespt_BR
dc.rightsopenAccesspt_BR
dc.subjectattenuation
dc.subjectavailability
dc.subjectdesign
dc.subjectlayers
dc.subjectpatients
dc.subjectphantoms
dc.subjectpmma
dc.subjectradiology
dc.subjectstability
dc.subjectstandards
dc.subjectx radiation
dc.titleAttenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorGLAUCO ROGERIO VENEZIANI
ipen.codigoautor1195
ipen.codigoautor346
ipen.codigoautor7498
ipen.codigoautor8988
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorGLAUCO ROGERIO VENEZIANI
ipen.date.recebimento17-09pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc23121pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublication8cc42bbc-1896-4124-b001-530bf4ab2773
relation.isAuthorOfPublication.latestForDiscovery8cc42bbc-1896-4124-b001-530bf4ab2773
sigepi.autor.atividadeVENEZIANI, G.R.:8988:330:Spt_BR
sigepi.autor.atividadeCORREA, E.L.:7498:330:Npt_BR
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23121.pdf
Tamanho:
1009.02 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções