Resumo
A water-cooled XY-type beam current monitor was designed, manufactured and assembled in a cyclotron accelerator beam transport line. Tests were performed, demonstrating that apparatus is an instrument of great assistance in proton beam position. The XY-type beam current monitor has been widely used in liquid target irradiations, employing irradiation system which were originally designed for irradiations on 18 MeV cyclotron accelerator (Cyclone 18, IBA) only, however, with this apparatus, the target may be exchanged between the 30 MeV (Cyclone 30, IBA) and 18 MeV cyclotrons.

Como referenciar
BARCELLOS, HENRIQUE; MATSUDA, HYLTON; LAPOLLI, ANDRE L.; SUMIYA, LUIZ C. do A.; JUNQUEIRA, FERNANDO de C.; COSTA, OSVALDO L. da. Design and assembly of an XY-type beam current monitor for cyclotron accelerators. Applied Radiation and Isotopes, v. 192, p. 1-5, 2023. DOI: 10.1016/j.apradiso.2022.110550. Disponível em: http://repositorio.ipen.br/handle/123456789/33479. Acesso em: 26 Apr 2024.