Artigo IPEN-doc 31167 Development of a sample exchange system for irradiations in the BH-3 channel of the IEA-R1 reactor at IPEN2024 - PAULA, M.L. de; MORALLES, M.; GENEZINI, F.A.; SIQUEIRA, P.T.D.; RIBEIRO JUNIOR, I.S.; SILVA JUNIOR, I.A. daThis work was developed with the aim of improving the current sample exchange system of the BH-3 irradiation channel of the IEA-R1 reactor at IPEN. The instrument's operating concept will provide a better use of the irradiation space as well as greater safety and confidence to the operator. The development of the system involved 3D modeling, sizing, construction and non-destructive testing of the various parts, and analysis of neutron-induced activation of the materials most exposed to the beam. A programmable logic controller (PLC) was implemented for the system’s control inside a dedicated electrical panel that was built with materials compatible with the location. The system was designed to support samples weighing up to 15 kg. Bench tests were carried out and showed that the system performs the necessary functions to accurately position samples in three locations: outside the biological shield, at the irradiation channel and at the decay waiting station. The implementation of this instrument will contribute to the application of the ALARA principle in the operator activities at the BH-3 irradiation channel.Artigo IPEN-doc 27119 Variability2020 - SILVA JÚNIOR, IREMAR A. da; SIQUEIRA, PAULO de T.D.; NASCIMENTO, EDUARDO do; YORIYAZ, HELIO; SORDI, GIAN-MARIA A.A.; POTIENS, MARIA da P.A.In this paper we present the impact of variability, a surface source parameter, on the efficiency evaluation of surface contamination monitors. This study was based on two source uniformity correction methodologies and data from real surface source distributions. Surface source intensity distribution has been changed by rearranging the cells (portions of the active area of each LARS) while keeping the same source uniformity value. Instrument efficiencies have been calculated for different sets of uniformities and variabilities. This study led to emphasize the importance of variability, a differential source intensity distribution parameter, over the uniformity, an integral source intensity distribution parameter, and reinforced the importance of the source uniformity correction procedure on the course of surface contamination monitor calibration.Artigo IPEN-doc 27117 Correction factors for non-uniform large-area reference sources2020 - SILVA JÚNIOR, IREMAR A.; SIQUEIRA, PAULO de T.D.; NASCIMENTO, EDUARDO do; YORIYAZ, HELIO; SORDI, GIAN-MARIA A.A.; VIVOLO, VITOR; POTIENS, MARIA da P.A.Based on uniformity measurements of large-area reference sources used in calibration procedures of surface contamination monitors, an investigation was carried out to obtain a method that estimates the bias originated from surface source intensity distribution deviation from the ideal uniform distribution and corrects it. It relies on correcting the estimated instrument efficiency by applying correction factors driven from the uniformity distribution profiles of the sources used in calibration procedure. Simulations of the monitor calibration procedure are run for 2 distinct surface source distributions: the real and the ideally uniform distributions. Correction factors are driven from counting rate estimates obtained from each source representation. In order to evaluate adequacy of this proposition it was validated against a method proposed by the NPL in the Good Practices Guide No.14.Artigo IPEN-doc 25846 Verification of angular dependence in MOSFET detector2019 - SOUZA, C.H.; SHORTO, J.M.B.; SIQUEIRA, P.T.D.; NUNES, M.G.; SILVA JUNIOR, I.A.; YORIYAZ, H.In vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of meas-urement, as well as easy handling. Nevertheless, its true differential is to allow reading of dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in the patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Exper-imental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (±1 SD) for Cs-137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient.Artigo IPEN-doc 24436 Avaliação da uniformidade de fonte extensa de referência circular e aplicação de fatores de correção2017 - SILVA JUNIOR, I.A.; XAVIER, M.; SIQUEIRA, P.T.D.; SORDI, G.A.A.; POTIENS, M.P.A.Neste trabalho é avaliada a uniformidade de fontes extensas de referência circular, que ainda são bastante utilizadas no Brasil. Em trabalhos anteriores foram analisadas fontes extensas de referência retangular mostrando-se a importância da aplicação de fatores de correção na calibração de monitores de radiação. Agora é realizada uma transposição de métodos usados então, avaliando-se as uniformidades de fontes de referência circular e calculando-se os fatores de correção associados.Artigo IPEN-doc 24419 Comparação entre duas metodologias para correção da uniformidade de fontes extensas de referência2017 - SILVA JUNIOR, I.A.; SIQUEIRA, P.T.D.; NASCIMENTO, E.; VIVOLO, V.; POTIENS, M.P.A.São apresentados neste artigo os procedimentos para obtenção de fatores de correção de uniformidade de fontes ex- tensas de referência sugerida por duas metodologias distintas. A primeira metodologia é apresentada pelo Guia de Boas Práticas do Nº 14 do NPL, que oferece uma correção numérica e a segunda é uma correção que utiliza o código de transporte de radiação, MCNP5. Ambos os métodos resultam na proposição de valores de correções muito simila- res percentualmente, com desvio máximo de 0,24%.Artigo IPEN-doc 24053 Verification of angular dependence in mosfet detector2017 - SOUZA, CLAYTON H.; SHORTO, JULIAN M.B.; SIQUEIRA, PAULO T.D.; NUNES, MAIRA G.; SILVA JUNIOR, IREMAR A.; YORIYAZ, HELIOIn vivo dosimetry is an essential tool for quality assurance programs, being a procedure commonly performed with thermoluminescent dosimeters (TLDs) or diodes. However, a type of dosimeter that has increasing popularity in recent years is the metal-oxide-semiconductor field effect transistor (MOSFET) detector. MOSFET dosimeters fulfill all the necessary characteristics to realize in vivo dosimetry since it has a small size, good precision and feasibility of measurement, as well as easy handling. Nevertheless, its true differential is to allow reading of the dose in real time, enabling immediate intervention in the correction of physical parameters deviations and anticipation of small anatomical changes in a patient during treatment. In order for MOSFET dosimeter to be better accepted in clinical routine, information reporting performance should be available frequently. For this reason, this work proposes to verify reproducibility and angular dependence of a standard sensitivity MOSFET dosimeter (TN-502RD-H) for Cs-137 and Co-60 sources. Experimental data were satisfactory and MOSFET dosimeter presented a reproducibility of 3.3% and 2.7% (1 SD) for Cs-137 and Co-60 sources, respectively. In addition, an angular dependence of up to 6.1% and 16.3% for both radioactive sources, respectively. It is conclusive that MOSFET dosimeter TN-502RD-H has satisfactory reproducibility and a considerable angular dependence, mainly for the Co-60 source. This means that although precise measurements, special attention must be taken for applications in certain anatomical regions in a patient.Artigo IPEN-doc 22686 Comparação entre duas metodologias para correção da uniformidade de fontes extensas de referência2016 - SILVA JUNIOR, IREMAR A.; SIQUEIRA, PAULO de T.D.; NACIMENTO, EDUARDO; VIVOLO, VITOR; POTIENS, MARIA da P.A.São apresentados neste artigo os procedimentos para obtenção de fatores de correção de uniformidade de fontes extensas de referência sugeridos por duas metodologias distintas. A primeira metodologia é apresentada pelo Guia de Boas Práticas do Nº 14 do NPL, que oferece uma correção numérica e a segunda é uma correção que utiliza o código de transporte de radiação, MCNP5. Ambos os métodos resultam na proposição de valores de correções muito similares percentualmente, com desvio máximo de 0,24%.Artigo IPEN-doc 21093 Overcoming the reference large-area sources non-uniformity in surface area monitor calibration2015 - SILVA JUNIOR, IREMAR A.; SIQUEIRA, PAULO de T.D.; XAVIER, MARCOS; NASCIMENTO, EDUARDO do; POTIENS, MARIA da P.A.