Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry
Carregando...
Data
Data de publicação
Autores IPEN
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Radiation Protection Dosimetry
Resumo
The dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied
in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed
dose, and the TL peaks appear at 110 and 170ºC. However, these sand samples present a post-irradiation thermal decay at
room temperature, which is a problem for dosimetric procedures. In this study, sand samples have been studied in relation to
different thermal treatments. Post-irradiation treatments were performed at 50ºC up to 230ºC.
Como referenciar
CALDAS, LINDA V.E.; TEIXEIRA, MARIA I.; FERRAZ, GILBERTO M. Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry. Radiation Protection Dosimetry, v. 120, n. 1-4, p. 230-234, 2006. DOI: 10.1093/rpd/nci660. Disponível em: http://repositorio.ipen.br/handle/123456789/5437. Acesso em: 30 Dec 2025.