Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry

dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.contributor.authorTEIXEIRA, MARIA I.pt_BR
dc.contributor.authorFERRAZ, GILBERTO M.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:48:07Zpt_BR
dc.date.accessioned2014-07-30T11:51:14Z
dc.date.available2014-07-15T13:48:07Zpt_BR
dc.date.available2014-07-30T11:51:14Z
dc.date.issued2006pt_BR
dc.description.abstractThe dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed dose, and the TL peaks appear at 110 and 170ºC. However, these sand samples present a post-irradiation thermal decay at room temperature, which is a problem for dosimetric procedures. In this study, sand samples have been studied in relation to different thermal treatments. Post-irradiation treatments were performed at 50ºC up to 230ºC.
dc.format.extent230-234pt_BR
dc.identifier.citationCALDAS, LINDA V.E.; TEIXEIRA, MARIA I.; FERRAZ, GILBERTO M. Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry. <b>Radiation Protection Dosimetry</b>, v. 120, n. 1-4, p. 230-234, 2006. DOI: <a href="https://dx.doi.org/10.1093/rpd/nci660">10.1093/rpd/nci660</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5437.
dc.identifier.doi10.1093/rpd/nci660
dc.identifier.fasciculo1-4pt_BR
dc.identifier.issn0144-8420pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5437pt_BR
dc.identifier.vol120pt_BR
dc.relation.ispartofRadiation Protection Dosimetrypt_BR
dc.rightsclosedAccessen
dc.subjectthermoluminescencept_BR
dc.subjectdosimetrypt_BR
dc.subjectsandpt_BR
dc.subjectradiation detectorspt_BR
dc.subjectheat treatmentspt_BR
dc.subjectelectron spin resonancept_BR
dc.subjectpost-irradiation examinationpt_BR
dc.titleInfluence of thermal treatments on the response of sand radiation detectors for high-dose dosimetrypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARIA INES TEIXEIRA
ipen.autorLINDA V. E. CALDAS
ipen.codigoautor2431
ipen.codigoautor1495
ipen.contributor.ipenauthorMARIA INES TEIXEIRA
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.date.recebimento06-11pt_BR
ipen.identifier.fi0.446pt_BR
ipen.identifier.ipendoc11491pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication77e3728e-ac22-44ec-b407-8f95984cf27d
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication.latestForDiscovery7f46d4f4-dfd6-4485-a767-10df5b4f4f13
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:28:Spt_BR
sigepi.autor.atividadeTEIXEIRA, MARIA I.:2431:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
11491.pdf
Tamanho:
195.78 KB
Formato:
Adobe Portable Document Format

Coleções