dc.description.abstractObjective: To evaluate the radiation dose received by staff in spine surgeries, including those who are not considered occupationally exposed workers. Methods: All spinal surgeries performed in the same department during a period of 12 months were evaluated with regard to the exposure of surgeons, scrub nurses, and auxiliary personnel working in the operating room to radiation from C-arm fluoroscopy. Radiation was measured by 15 film badge dosimeters placed on the professionals’ lapels, gloves, and room standardized sites. The films were analyzed in the dosimetry laboratory by collections per period. Results: During the 12 months, 81 spinal surgeries were performed by the same team, with surgical times ranging from 1 to 6 hours. The total radiation dose ranged from 0.16 mSv to 2.29 mSv depending on the dosimetry site. The most exposed site was the wrist of the main surgeon. Conclusion: The results showed that in the spinal surgeries in our setting, the radiation doses are low and within legal limits. Nevertheless, constant training of professionals is essential for radiation protection of medical staff and patients. Level of evidence I/b, exploratory cohort study.pt_BR
dc.format.extent46-49pt_BR
dc.identifier.citationCRISTANTE, ALEXANDRE F.; BARBIERI, FABIO; SILVA, ALMY A.R. da; DELLAMANO, JOSE C. Radiation exposure during spine surgery using C-arm fluoroscopy. <b>Acta Ortopédica Brasileira</b>, v. 27, n. 1, p. 46-49, 2019. DOI: <a href="https://dx.doi.org/10.1590/1413-785220192701172722">10.1590/1413-785220192701172722</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/30025.
dc.identifier.doi10.1590/1413-785220192701172722pt_BR
dc.identifier.fasciculo1pt_BR
dc.identifier.issn1413-7852pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8999-8548
dc.identifier.percentilfi4.268
dc.identifier.percentilfiCiteScore32.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30025
dc.identifier.vol27pt_BR
dc.relation.ispartofActa Ortopédica Brasileirapt_BR
dc.rightsopenAccesspt_BR
dc.subjectradiation absorption analysis
dc.subjectradiation doses
dc.subjectfluoroscopy
dc.subjectspinels
dc.subjectsurgery
dc.titleRadiation exposure during spine surgery using C-arm fluoroscopypt_BR
dc.title.alternativeExposição a radiação durante cirurgias de coluna com radisocopiapt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorJOSE CLAUDIO DELLAMANO
ipen.codigoautor146
ipen.contributor.ipenauthorJOSE CLAUDIO DELLAMANO
ipen.date.recebimento19-08
ipen.identifier.fi0.570pt_BR
ipen.identifier.fiCiteScore0.9
ipen.identifier.ipendoc25817pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi0.00 - 24.99
ipen.type.genreArtigo
relation.isAuthorOfPublication1b4c52dc-227a-426b-881e-8598bc07bf86
relation.isAuthorOfPublication.latestForDiscovery1b4c52dc-227a-426b-881e-8598bc07bf86
sigepi.autor.atividadeDELLAMANO, JOSE C.:146:450:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25817.pdf
Tamanho:
279.89 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções