Dose-rate constant and air-kerma strength evaluation of a new 125I brachytherapy source using Monte-Carlo

dc.contributor.authorPRIMO, C.O.pt_BR
dc.contributor.authorANGELOCCI, L.V.pt_BR
dc.contributor.authorKARAM JUNIOR, D.pt_BR
dc.contributor.authorZEITUNI, C.A.pt_BR
dc.contributor.authorROSTELATO, M.E.C.M.pt_BR
dc.coverageNacionalpt_BR
dc.date.accessioned2021-08-03T15:01:36Z
dc.date.available2021-08-03T15:01:36Z
dc.date.issued2021pt_BR
dc.description.abstractBrachytherapy is a modality of radiotherapy which treats tumors using ionizing radiation with sources located close to the tumor. The sources can be produced from several radionuclides in various formats, such as Iodine-125 seeds and Iridium-192 wires. In order to produce a new Iodine-125 seed in IPEN/CNEN and ensure its quality, it is essential to describe the seed dosimetry, so when applied in a treatment the lowest possible dose to neighboring healthy tissues can be reached. The report by the AAPM’s Task Group 43 U1 is a document that indicates the dosimetry procedures in brachytherapy based on physical and geometrical parameters. In this study, dose-rate constant and air-kerma strength parameters were simulated using the Monte Carlo radiation transport code MCNP4C. The air-kerma strength is obtained from an ideal modeled seed, since its actual value should be measured for seeds individually in a specialized lab with a Wide-Angle Free-Air Chamber (WAFAC). Dose-rate constant and air-kerma strength are parameters that depends on intrinsic characteristics of the source, i.e. geometry, radionuclide, encapsulation, and together they define the dose-rate to the reference point. Radial dose function describes the dose fall-off with distance from the source. This study presents the values found for these parameters with associated statistical uncertainty, and is part of a larger project that aims the full dosimetry of this new seed model, including experimental measures.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipInternational Atomic Energy Agency (IAEA)pt_BR
dc.description.sponsorshipIDCNPq: 133764/2019-2pt_BR
dc.description.sponsorshipIDCAPES: 88882.333477/2019-01; 001pt_BR
dc.description.sponsorshipIDIAEA: BRA17013; BRA6026pt_BR
dc.format.extent1-11pt_BR
dc.identifier.citationPRIMO, C.O.; ANGELOCCI, L.V.; KARAM JUNIOR, D.; ZEITUNI, C.A.; ROSTELATO, M.E.C.M. Dose-rate constant and air-kerma strength evaluation of a new 125I brachytherapy source using Monte-Carlo. <b>Brazilian Journal of Radiation Sciences</b>, v. 9, n. 1A, p. 1-11, 2021. DOI: <a href="https://dx.doi.org/10.15392/bjrs.v9i1A.1441">10.15392/bjrs.v9i1A.1441</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32116.
dc.identifier.doi10.15392/bjrs.v9i1A.1441pt_BR
dc.identifier.fasciculo1Apt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.orcid0000-0003-2943-6097pt_BR
dc.identifier.orcid0000-0002-7303-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-2943-6097
dc.identifier.orcidhttps://orcid.org/0000-0002-7303-6720
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32116
dc.identifier.vol9pt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsopenAccesspt_BR
dc.sourceMeeting on Nuclear Applications (ENAN), 14th, October 21-25, 2019, Santos, SPpt_BR
dc.subjectbrachytherapy
dc.subjectcomputerized simulation
dc.subjectdose rates
dc.subjectdosimetry
dc.subjectiodine 125
dc.subjectkerma
dc.subjectmonte carlo method
dc.titleDose-rate constant and air-kerma strength evaluation of a new 125I brachytherapy source using Monte-Carlopt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLUCAS VERDI ANGELOCCI
ipen.autorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.autorCARLOS ALBERTO ZEITUNI
ipen.autorCAMILA DE OLIVEIRA PRIMO
ipen.codigoautor12698
ipen.codigoautor7
ipen.codigoautor944
ipen.codigoautor14989
ipen.contributor.ipenauthorLUCAS VERDI ANGELOCCI
ipen.contributor.ipenauthorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.contributor.ipenauthorCARLOS ALBERTO ZEITUNI
ipen.contributor.ipenauthorCAMILA DE OLIVEIRA PRIMO
ipen.date.recebimento21-08
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc27887pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication34f99ea4-8545-4c90-80e2-e9fda638cd8c
relation.isAuthorOfPublicationda77b491-04ff-4c68-aa65-dead9208a48c
relation.isAuthorOfPublication02421b96-adef-4759-b25e-67d4759aa676
relation.isAuthorOfPublicationa548b7e2-662a-4281-9e07-77e362e7b148
relation.isAuthorOfPublication.latestForDiscoverya548b7e2-662a-4281-9e07-77e362e7b148
sigepi.autor.atividadeROSTELATO, M.E.C.M.:7:230:Npt_BR
sigepi.autor.atividadeZEITUNI, C.A.:944:230:Npt_BR
sigepi.autor.atividadeANGELOCCI, L.V.:12698:230:Npt_BR
sigepi.autor.atividadePRIMO, C.O.:14989:230:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27887.pdf
Tamanho:
788.21 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções