Angular dependence of an intercomparison system in low and medium energies of X-rays beams

Carregando...
Imagem de Miniatura

Data

Data de publicação

2004

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
Ionization chambers are radiation detectors widely used for Xrays measurements and quality control tests in diagnostic radiology. In radiotherapy, the ionization chambers are used for determining the absorbed dose delivered to the patient. An ionization chamber can take many forms, but the principle of operation is similar for all chambers. It is based on the collection of charges created by the passage of radiation, with a proper voltage maintained between the wall of the chamber and the central electrode. In this work, the dependence of detector response on angle of incident radiation was evaluated for three ionization chambers used as an intercomparison standard system in low and medium x-ray beams. The ionization chambers tested are Victoreen guarded electrode with an approximately air equivalent wall, models 415, 415A and 415B. The guarded electrode construction permits direct current measurement with a minimum amount of drift. The irradiations were carried out using two different systems: a) Rigaku Denki generator, model Geigerflex, with a Philips tube model PW/2184/00 (tungsten target and beryllium window, 60 kV), and b) Pantak model HF 320 (tungsten target and beryllium window, 320 kV). All measurements were carried out in reference conditions. The variation of the response for the chamber model 415A, was verified in function of the plane of the entrance window tilted by ±5° from its reference position, perpendicular to the axis of the radiation beam, according to international recommendations. The tests were performed measuring the chamber response, at tilt angles of 1° apart. For models 415 and 415B respectively, the chambers were rotated around their central axis from – 180° to +180° in steps of 30°. The responses of the chambers were normalized to the reference position (0°), and the results obtained meet the international recommendations, i.e., the limits of variation of response are within ±1.0%.

Como referenciar
ROCHA, F.D.G.; ALVAREZ, O.T.B.; CALDAS, L.V.E. Angular dependence of an intercomparison system in low and medium energies of X-rays beams. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th, 23-28 May, 2004, Madrid, Spain. Disponível em: http://repositorio.ipen.br/handle/123456789/19910. Acesso em: 27 Mar 2026.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento