Angular dependence of an intercomparison system in low and medium energies of X-rays beams

dc.contributor.authorROCHA, F.D.G.pt_BR
dc.contributor.authorALVAREZ, O.T.B.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11thpt_BR
dc.date.accessioned2014-11-19T10:51:10Zpt_BR
dc.date.accessioned2014-11-19T14:09:49Zpt_BR
dc.date.accessioned2015-04-01T12:48:17Z
dc.date.available2014-11-19T10:51:10Zpt_BR
dc.date.available2014-11-19T14:09:49Zpt_BR
dc.date.available2015-04-01T12:48:17Z
dc.date.evento23-28 May, 2004pt_BR
dc.description.abstractIonization chambers are radiation detectors widely used for Xrays measurements and quality control tests in diagnostic radiology. In radiotherapy, the ionization chambers are used for determining the absorbed dose delivered to the patient. An ionization chamber can take many forms, but the principle of operation is similar for all chambers. It is based on the collection of charges created by the passage of radiation, with a proper voltage maintained between the wall of the chamber and the central electrode. In this work, the dependence of detector response on angle of incident radiation was evaluated for three ionization chambers used as an intercomparison standard system in low and medium x-ray beams. The ionization chambers tested are Victoreen guarded electrode with an approximately air equivalent wall, models 415, 415A and 415B. The guarded electrode construction permits direct current measurement with a minimum amount of drift. The irradiations were carried out using two different systems: a) Rigaku Denki generator, model Geigerflex, with a Philips tube model PW/2184/00 (tungsten target and beryllium window, 60 kV), and b) Pantak model HF 320 (tungsten target and beryllium window, 320 kV). All measurements were carried out in reference conditions. The variation of the response for the chamber model 415A, was verified in function of the plane of the entrance window tilted by ±5° from its reference position, perpendicular to the axis of the radiation beam, according to international recommendations. The tests were performed measuring the chamber response, at tilt angles of 1° apart. For models 415 and 415B respectively, the chambers were rotated around their central axis from – 180° to +180° in steps of 30°. The responses of the chambers were normalized to the reference position (0°), and the results obtained meet the international recommendations, i.e., the limits of variation of response are within ±1.0%.
dc.event.siglaIRPApt_BR
dc.identifier.citationROCHA, F.D.G.; ALVAREZ, O.T.B.; CALDAS, L.V.E. Angular dependence of an intercomparison system in low and medium energies of X-rays beams. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th, 23-28 May, 2004, Madrid, Spain. Disponível em: http://repositorio.ipen.br/handle/123456789/19910.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/19910pt_BR
dc.local.eventoMadrid, Spainpt_BR
dc.rightsopenAccesspt_BR
dc.subjectionization chamberspt_BR
dc.subjectx radiationpt_BR
dc.subjectradiotherapypt_BR
dc.subjectdiagnostic techniquespt_BR
dc.titleAngular dependence of an intercomparison system in low and medium energies of X-rays beamspt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorOSCAR TEODULO BORDON ALVAREZ
ipen.autorFELICIA DEL GALLO ROCHA
ipen.codigoautor1495
ipen.codigoautor2002
ipen.codigoautor1806
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorOSCAR TEODULO BORDON ALVAREZ
ipen.contributor.ipenauthorFELICIA DEL GALLO ROCHA
ipen.date.recebimento05-10pt_BR
ipen.event.datapadronizada2004pt_BR
ipen.identifier.ipendoc10816pt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication72cd1df3-a918-45fc-8a76-07a92b8350f7
relation.isAuthorOfPublicationdfb00f48-ec5f-4d13-9050-7097d6232849
relation.isAuthorOfPublication.latestForDiscoverydfb00f48-ec5f-4d13-9050-7097d6232849
sigepi.autor.atividadeROCHA, F.D.G.:1806:-1:Spt_BR
sigepi.autor.atividadeALVAREZ, O.T.B.:2002:28:Npt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
10816.pdf
Tamanho:
5.58 KB
Formato:
Adobe Portable Document Format