Radiosurgery dosimetry using CaSO4:Eu OSLD film

dc.contributor.authorGASPARIAN, PATRICIA B.R.
dc.contributor.authorMALTHEZ, ANNA L.M.C.
dc.contributor.authorTORQUATO, MICHELE
dc.contributor.authorCAMPOS, LETICIA L.
dc.coverageInternacional
dc.date.accessioned2024-03-25T20:03:17Z
dc.date.available2024-03-25T20:03:17Z
dc.date.issued2023
dc.description.abstractRecent studies demonstrated that optically stimulated luminescence (OSL) systems allow the evaluation of doses for 2D mapping in a relatively fast and simple way and results show submillimeter resolution. This work presents, for the first time, an optically stimulated luminescence dosemeter (OSLD) in the form of film made with CaSO4:Eu particles embedded in a silicone elastomer matrix. The OSLD film was produced using a low-cost and relatively simple methodology. This film is reusable and the signal can be satisfactorily bleached using blue LEDs. The main dosimetric properties were evaluated using TL/OSL Risø reader with blue stimulation and Hoya U-340 filter. Investigation shows repeatability within 3% when measuring with the same film sample. Regarding the OSLD film homogeneity, nearly 12% sensitivity change was observed within the 5 × 5 cm2 produced film. Additionally, the dose response curve shows linearity from 5 to 25 Gy. Fading of the OSL signal is relatively high, about 50% in the first week and then is stable. Nevertheless, a 3 × 3 cm2 OSLD film was successfully used to map dose distribution in radiosurgery (6 MV photon beam). This work demonstrates the feasibility of 2D dosimetry using reusable OSLD films based on CaSO4:Eu.
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIDFAPESP: 18/05982-0
dc.description.sponsorshipIDCNPq: 426513/2018-5
dc.format.extent1040-1046
dc.identifier.citationGASPARIAN, PATRICIA B.R.; MALTHEZ, ANNA L.M.C.; TORQUATO, MICHELE; CAMPOS, LETICIA L. Radiosurgery dosimetry using CaSO4:Eu OSLD film: a feasibility study. <b>Radiation Protection Dosimetry</b>, v. 199, n. 8-9, p. 1040-1046, 2023. DOI: <a href="https://dx.doi.org/10.1093/rpd/ncad109">10.1093/rpd/ncad109</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/48001.
dc.identifier.doi10.1093/rpd/ncad109
dc.identifier.fasciculo8-9
dc.identifier.issn0144-8420
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.percentilfi13.2
dc.identifier.percentilfiCiteScore28.75
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/48001
dc.identifier.vol199
dc.relation.ispartofRadiation Protection Dosimetry
dc.rightsopenAccess
dc.sourceEuropean Congress on Radiation Proctetion, 6th, May 30 - June 3, 2022, Budapest, Hungary
dc.subjectthermoluminescence
dc.subjectdosimetry
dc.subjectradiotherapy
dc.subjectsurgery
dc.subjectcalcium sulfates
dc.subjectdoped materials
dc.subjecteuropium
dc.subjectdose rates
dc.titleRadiosurgery dosimetry using CaSO4:Eu OSLD film
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorPATRICIA BERINGHS RIO
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.codigoautor7070
ipen.codigoautor1195
ipen.contributor.ipenauthorPATRICIA BERINGHS RIO
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.identifier.fi0.8
ipen.identifier.fiCiteScore1.4
ipen.identifier.ipendoc30343
ipen.identifier.iwosWoS
ipen.range.fi0.001 - 1.499
ipen.range.percentilfi0.00 - 24.99
ipen.subtituloa feasibility study
ipen.type.genreArtigo
relation.isAuthorOfPublication2c6b2429-cea9-4241-b7b3-7b5b20d13443
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication.latestForDiscovery2c6b2429-cea9-4241-b7b3-7b5b20d13443
sigepi.autor.atividadePATRICIA BERINGHS RIO:7070:330:S
sigepi.autor.atividadeLETICIA LUCENTE CAMPOS RODRIGUES:1195:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30343.pdf
Tamanho:
621.56 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções