Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019

dc.contributor.authorCABRAL, T.S.pt_BR
dc.contributor.authorLARANJEIRA, A.S.pt_BR
dc.contributor.authorPOTIENS, M.P.A.pt_BR
dc.contributor.authorSOARES, C.M.A.pt_BR
dc.contributor.authorKHOURY, H.pt_BR
dc.contributor.authorSAITO, V.pt_BR
dc.contributor.authorDAVID, M.pt_BR
dc.contributor.authorVIDAL, L.C.pt_BR
dc.contributor.authorPIRES, M.A.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2021-07-21T12:23:06Z
dc.date.available2021-07-21T12:23:06Z
dc.date.issued2021pt_BR
dc.description.abstractThis work reports the results obtained from the comparison involving 7 laboratories in Brazil. This exercise is about the calibration service of surface contamination monitors. The monitor has been calibrated to BS ISO 7503-3, the calibration factor in terms of surface emission rate. The comparison was conducted by the Brazilian National Laboratory of Ionizing Radiation Metrology (LNMRI / IRD) from October 2018 to July 2019. The extensive sources used were 14C, 137Cs, 60Co, 90Sr/90Y, 36Cl and 241Am. The result of this proficiency test was excellent and proved the calibration capacity of the Brazilian network in the calibration service for surface contamination monitors.pt_BR
dc.format.extent1-6pt_BR
dc.identifier.citationCABRAL, T.S.; LARANJEIRA, A.S.; POTIENS, M.P.A.; SOARES, C.M.A.; KHOURY, H.; SAITO, V.; DAVID, M.; VIDAL, L.C.; PIRES, M.A. Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019. <b>Journal of Physics: Conference Series</b>, v. 1826, p. 1-6, 2021. DOI: <a href="https://dx.doi.org/10.1088/1742-6596/1826/1/012039">10.1088/1742-6596/1826/1/012039</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32032.
dc.identifier.doi10.1088/1742-6596/1826/1/012039pt_BR
dc.identifier.issn1742-6588pt_BR
dc.identifier.orcid0000-0002-4049-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfiSem Percentilpt_BR
dc.identifier.percentilfiCiteScore18.00
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/32032
dc.identifier.vol1826pt_BR
dc.relation.ispartofJournal of Physics: Conference Seriespt_BR
dc.rightsopenAccesspt_BR
dc.sourceBrazilian Congress on Metrology, 10th, November 24-27, 2019, Florianopolis, SCpt_BR
dc.subjectcalibration standards
dc.subjectinterlaboratory comparisons
dc.subjectiso
dc.subjectradiation protection
dc.subjectradiation sources
dc.subjectsurface contamination monitors
dc.titleComparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019pt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.codigoautor346
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.date.recebimento21-07
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.fiCiteScore0.8
ipen.identifier.ipendoc27803pt_BR
ipen.identifier.ods7
ipen.identifier.ods9
ipen.identifier.ods12
ipen.type.genreArtigo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication.latestForDiscovery30f213ae-321d-4d51-8763-0a2585255fb9
sigepi.autor.atividadePOTIENS, M.P.A.:346:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27803.pdf
Tamanho:
1.47 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções