Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019
| dc.contributor.author | CABRAL, T.S. | pt_BR |
| dc.contributor.author | LARANJEIRA, A.S. | pt_BR |
| dc.contributor.author | POTIENS, M.P.A. | pt_BR |
| dc.contributor.author | SOARES, C.M.A. | pt_BR |
| dc.contributor.author | KHOURY, H. | pt_BR |
| dc.contributor.author | SAITO, V. | pt_BR |
| dc.contributor.author | DAVID, M. | pt_BR |
| dc.contributor.author | VIDAL, L.C. | pt_BR |
| dc.contributor.author | PIRES, M.A. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2021-07-21T12:23:06Z | |
| dc.date.available | 2021-07-21T12:23:06Z | |
| dc.date.issued | 2021 | pt_BR |
| dc.description.abstract | This work reports the results obtained from the comparison involving 7 laboratories in Brazil. This exercise is about the calibration service of surface contamination monitors. The monitor has been calibrated to BS ISO 7503-3, the calibration factor in terms of surface emission rate. The comparison was conducted by the Brazilian National Laboratory of Ionizing Radiation Metrology (LNMRI / IRD) from October 2018 to July 2019. The extensive sources used were 14C, 137Cs, 60Co, 90Sr/90Y, 36Cl and 241Am. The result of this proficiency test was excellent and proved the calibration capacity of the Brazilian network in the calibration service for surface contamination monitors. | pt_BR |
| dc.format.extent | 1-6 | pt_BR |
| dc.identifier.citation | CABRAL, T.S.; LARANJEIRA, A.S.; POTIENS, M.P.A.; SOARES, C.M.A.; KHOURY, H.; SAITO, V.; DAVID, M.; VIDAL, L.C.; PIRES, M.A. Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019. <b>Journal of Physics: Conference Series</b>, v. 1826, p. 1-6, 2021. DOI: <a href="https://dx.doi.org/10.1088/1742-6596/1826/1/012039">10.1088/1742-6596/1826/1/012039</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/32032. | |
| dc.identifier.doi | 10.1088/1742-6596/1826/1/012039 | pt_BR |
| dc.identifier.issn | 1742-6588 | pt_BR |
| dc.identifier.orcid | 0000-0002-4049-6720 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-4049-6720 | |
| dc.identifier.percentilfi | Sem Percentil | pt_BR |
| dc.identifier.percentilfiCiteScore | 18.00 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/32032 | |
| dc.identifier.vol | 1826 | pt_BR |
| dc.relation.ispartof | Journal of Physics: Conference Series | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | Brazilian Congress on Metrology, 10th, November 24-27, 2019, Florianopolis, SC | pt_BR |
| dc.subject | calibration standards | |
| dc.subject | interlaboratory comparisons | |
| dc.subject | iso | |
| dc.subject | radiation protection | |
| dc.subject | radiation sources | |
| dc.subject | surface contamination monitors | |
| dc.title | Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019 | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARIA DA PENHA ALBUQUERQUE POTIENS | |
| ipen.codigoautor | 346 | |
| ipen.contributor.ipenauthor | MARIA DA PENHA ALBUQUERQUE POTIENS | |
| ipen.date.recebimento | 21-07 | |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.fiCiteScore | 0.8 | |
| ipen.identifier.ipendoc | 27803 | pt_BR |
| ipen.identifier.ods | 7 | |
| ipen.identifier.ods | 9 | |
| ipen.identifier.ods | 12 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 30f213ae-321d-4d51-8763-0a2585255fb9 | |
| relation.isAuthorOfPublication.latestForDiscovery | 30f213ae-321d-4d51-8763-0a2585255fb9 | |
| sigepi.autor.atividade | POTIENS, M.P.A.:346:330:N | pt_BR |