New Fricke Xylenol Liquid detector doped with methylene blue (FXL-mblue) irradiated with red LED light

dc.contributor.authorOLIVEIRA, LUCAS N. dept_BR
dc.contributor.authorNASCIMENTO, ERIBERTO O. dopt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2021-04-05T17:20:51Z
dc.date.available2021-04-05T17:20:51Z
dc.date.issued2021pt_BR
dc.description.abstractIn photodynamic therapy, a beam of incident light on the target causes interactions with the photosensitizing agent in the patient, subsequently killing cancerous cells through chemical and biological processes. The objective of this work was to describe for the first time the use of the FXL-mblue detector in dosimetric applications with irradiations from red LED light and using the UV–Vis spectrophotometry as an evaluation technique. The FXL-mblue samples were irradiated with doses of 2.40 kJ/cm2 up to 21.6 kJ/cm2 using a red LED light system. The results showed good results on uncertainties, sensitivity, reproducibility, repeatability, minimum detectable dose (MDD) and fading times for a promising dosimeter in measurements with visible light. In conclusion, the results indicate good dosimetric characteristics which could be used in quality control of photodynamic therapy measurements.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipIDCNPq: 104486/2019-8; 301335/2016-8pt_BR
dc.description.sponsorshipIDFAPESP: 18/05982-0pt_BR
dc.format.extent1-9pt_BR
dc.identifier.citationOLIVEIRA, LUCAS N. de; NASCIMENTO, ERIBERTO O. do; CALDAS, LINDA V.E. New Fricke Xylenol Liquid detector doped with methylene blue (FXL-mblue) irradiated with red LED light. <b>Journal of Luminescence</b>, v. 230, p. 1-9, 2021. DOI: <a href="https://dx.doi.org/10.1016/j.jlumin.2020.117730">10.1016/j.jlumin.2020.117730</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/31962.
dc.identifier.doi10.1016/j.jlumin.2020.117730pt_BR
dc.identifier.issn0022-2313pt_BR
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.percentilfi74.75pt_BR
dc.identifier.percentilfiCiteScore80.20
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31962
dc.identifier.vol230pt_BR
dc.relation.ispartofJournal of Luminescencept_BR
dc.rightsopenAccesspt_BR
dc.subjectchemical dosemeters
dc.subjectdosemeters
dc.subjectxylenols
dc.subjectmethylene blue
dc.subjectlight emitting diodes
dc.subjectultraviolet spectrometers
dc.subjecttherapy
dc.subjectphotosensitivity
dc.titleNew Fricke Xylenol Liquid detector doped with methylene blue (FXL-mblue) irradiated with red LED lightpt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorLUCAS NONATO DE OLIVEIRA
ipen.codigoautor1495
ipen.codigoautor10632
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorLUCAS NONATO DE OLIVEIRA
ipen.date.recebimento21-04
ipen.identifier.fi4.171pt_BR
ipen.identifier.fiCiteScore6.9
ipen.identifier.ipendoc27733pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication87cc29f4-0e1f-4f7f-87ab-618b39834eb2
relation.isAuthorOfPublication.latestForDiscovery87cc29f4-0e1f-4f7f-87ab-618b39834eb2
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeOLIVEIRA, LUCAS N. de:10632:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27733.pdf
Tamanho:
4.68 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções