Dosimetric evaluation and comparation of TL responses of LiF:Mg,Ti and μLiF:Mg,Ti in the clinical electron beams dosimetry applied to total skin irradiation (TSEB) treatments

dc.contributor.authorALMEIDA, S.B.pt_BR
dc.contributor.authorVILLANI, D.pt_BR
dc.contributor.authorSAKURABA, R.K.pt_BR
dc.contributor.authorREZENDE, A.C.P.pt_BR
dc.contributor.authorCAMPOS, L.L.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2019-07-29T19:25:52Z
dc.date.available2019-07-29T19:25:52Z
dc.date.issued2019pt_BR
dc.description.abstractThe Total Skin Electron Beam (TSEB) irradiation is a radiotherapeutic technique that aims to provide the patient's skin surface with a more homogeneous dose, in order to treat cutaneous T-cell lymphomas, both for curative and palliative purposes. Electron irradiation penetrates a few millimeters into the skin, reaching the affected parts completely, without penetrating the internal organs. In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. The LiF:Mg,Ti is the most used TL material and widely studied in radiotherapy dosimetry due to near tissue-equivalence of the material, along with its overall reliability. The dosimeters of μLiF:Mg,Ti have been gaining considerable importance in the radiotherapy departments. These detectors allow measurements in vivo with great advantages due to their minimum dimensions of 1×1×1 mm3. This paper reports a comparative study of the TL responses of both materials to dose evaluation in TSEB treatments. The TL response of both materials in several TSEB parameter tests and in clinical application were evaluated, analyzing the dose distribution in a treatment simulation using AldersonRando anthropomorphic phantom. The results showed that the μLiF:Mg,Ti presented greater variation of the response in relation to LiF dosemeters in some parameters analyzed, due to the small dimensions and to evaluate doses absorbed in the surface over a large area in the treatment plan.pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipIDCAPES: 554/2018pt_BR
dc.description.sponsorshipIDCNPq: 573659/2008-7pt_BR
dc.description.sponsorshipIDFAPESP: 10/16437-0pt_BR
dc.format.extent15-18pt_BR
dc.identifier.citationALMEIDA, S.B.; VILLANI, D.; SAKURABA, R.K.; REZENDE, A.C.P.; CAMPOS, L.L. Dosimetric evaluation and comparation of TL responses of LiF:Mg,Ti and μLiF:Mg,Ti in the clinical electron beams dosimetry applied to total skin irradiation (TSEB) treatments. <b>Radiation Measurements</b>, v. 125, p. 15-18, 2019. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2019.03.007">10.1016/j.radmeas.2019.03.007</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29975.
dc.identifier.doi10.1016/j.radmeas.2019.03.007pt_BR
dc.identifier.issn1350-4487pt_BR
dc.identifier.orcid0000-0001-7137-0613pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.percentilfi66.176pt_BR
dc.identifier.percentilfiCiteScore61.50
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29975
dc.identifier.vol125pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccesspt_BR
dc.subjectdosimetry
dc.subjectskin absorption
dc.subjectexternal irradiation
dc.subjecttherapy
dc.subjectradiotherapy
dc.subjectthermoluminescence
dc.subjectelectron beam injection
dc.subjectlymphomas
dc.titleDosimetric evaluation and comparation of TL responses of LiF:Mg,Ti and μLiF:Mg,Ti in the clinical electron beams dosimetry applied to total skin irradiation (TSEB) treatmentspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorDANIEL VILLANI
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorSHIRLANE BARBOSA DE ALMEIDA
ipen.codigoautor12762
ipen.codigoautor1195
ipen.codigoautor14033
ipen.contributor.ipenauthorDANIEL VILLANI
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorSHIRLANE BARBOSA DE ALMEIDA
ipen.date.recebimento19-07
ipen.identifier.fi1.512pt_BR
ipen.identifier.fiCiteScore2.9
ipen.identifier.ipendoc25760pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.identifier.ods3
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublication26698252-02e7-4d43-8ffb-edaf9f863fa2
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication2376fe21-10ec-46bd-b287-64478233f9ce
relation.isAuthorOfPublication.latestForDiscovery2376fe21-10ec-46bd-b287-64478233f9ce
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR
sigepi.autor.atividadeVILLANI, D.:12762:330:Npt_BR
sigepi.autor.atividadeALMEIDA, S.B.:14033:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25760.pdf
Tamanho:
615.22 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções