Energy dependent response of the Fricke gel dosimeter prepared with 270 bloom gelatine for photons in the energy range 13.93 KeV-6MeV
| dc.contributor.author | CAVINATO, C.C. | pt_BR |
| dc.contributor.author | CAMPOS, L.L. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:39:57Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:51:09Z | |
| dc.date.available | 2014-07-15T13:39:57Z | pt_BR |
| dc.date.available | 2014-07-30T11:51:09Z | |
| dc.date.issued | 2010 | pt_BR |
| dc.description.abstract | The spectrophotometric energy dependent response to photons with effective energies between 13.93 keV and 6 MeV of the Fricke xylenol gel (FXG) dosimeter developed at IPEN, prepared using 270 Bloom gelatine, was evaluated in order to verify the possible dosimeter application in other medicine areas in addition to radiosurgery, for example, breast radiotherapy and blood bags radiosterilization. Other dosimetric characteristics were also evaluated. The obtained results indicate that the FXG dosimeter can contribute to dosimetry in different medical application areas including magnetic resonance imaging (MRI) evaluation technique that permits three-dimensional (3D) dose distribution evaluation. | |
| dc.format.extent | 198-202 | pt_BR |
| dc.identifier.citation | CAVINATO, C.C.; CAMPOS, L.L. Energy dependent response of the Fricke gel dosimeter prepared with 270 bloom gelatine for photons in the energy range 13.93 KeV-6MeV. <b>Nuclear Instruments and Methods in Physics Research, A</b>, v. 619, n. 1-3, p. 198-202, 2010. DOI: <a href="https://dx.doi.org/10.1016/j.nima.2009.10.144">10.1016/j.nima.2009.10.144</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/4693. | |
| dc.identifier.doi | 10.1016/j.nima.2009.10.144 | |
| dc.identifier.fasciculo | 1-3 | pt_BR |
| dc.identifier.issn | 0168-9002 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0001-7137-0613 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/4693 | pt_BR |
| dc.identifier.vol | 619 | pt_BR |
| dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research, A | pt_BR |
| dc.rights | openAccess | en |
| dc.source | Apresentado tambem em: International Symposium on Radiation Physics, 11th, September 20-25, 2009, Melbourne, Australia | pt_BR |
| dc.subject | chemical dosemeters | pt_BR |
| dc.subject | spectrophotometry | pt_BR |
| dc.subject | energy dependence | pt_BR |
| dc.title | Energy dependent response of the Fricke gel dosimeter prepared with 270 bloom gelatine for photons in the energy range 13.93 KeV-6MeV | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LETICIA LUCENTE CAMPOS RODRIGUES | |
| ipen.autor | CHRISTIANNE COBELLO CAVINATO | |
| ipen.codigoautor | 1195 | |
| ipen.codigoautor | 3880 | |
| ipen.contributor.ipenauthor | LETICIA LUCENTE CAMPOS RODRIGUES | |
| ipen.contributor.ipenauthor | CHRISTIANNE COBELLO CAVINATO | |
| ipen.date.recebimento | 10-08 | pt_BR |
| ipen.identifier.fi | 1.142 | pt_BR |
| ipen.identifier.ipendoc | 15568 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | d4d34119-a6e6-4026-9a67-7b16d8b668da | |
| relation.isAuthorOfPublication | 7a92997b-7fa4-4eb0-b8f0-7157368c2158 | |
| relation.isAuthorOfPublication.latestForDiscovery | 7a92997b-7fa4-4eb0-b8f0-7157368c2158 | |
| sigepi.autor.atividade | CAVINATO, C.C.:3880:330:S | pt_BR |
| sigepi.autor.atividade | CAMPOS, L.L.:1195:330:N | pt_BR |
Pacote Original
1 - 1 de 1