Evaluation of a special parallel-plate ionization chamber for mammography and digital breast tomosynthesis dosimetry

Carregando...
Imagem de Miniatura

Data

Data de publicação

2024

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

SIMPOSIO REPROLAM, 1st
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
A special parallel-plate ionization chamber, developed at the Calibration Laboratory of IPEN (LCI), was tested to verify the possibility of its application in mammography and digital breast tomosynthesis dosimetry. It has a rectangular box geometric shape (146 mm x 46.4 mm x 24 mm), a sensitive length of 10 cm, and a sensitive volume of 3.2 cm3. The chamber wall is made of PMMA, its collecting electrode is made of graphite, and its chamber window is a Mylar foil. The chamber was submitted to several characterization and quality control tests: leakage current, short- and medium-term stabilities, stabilization time, saturation, ion collection efficiency, polarity effect, linearity of response, and angular dependence. The maximum value observed in the leakage current test was 0.53% so within the recommended limit of ±5% by the IEC 61674 standard. In the short-term stability test, the highest coefficient of variation obtained was 0.17%. This value satisfies the IEC 61674 standard requirements (±3%). The maximum value observed in the medium-term stability was below the recommended limit of ±2%. For the stabilization time test, the difference between the ionization currents obtained between 15 min and 60 min after switching on the measuring system was only 0.62%. This result is within the recommended limits of ±2% of response variation, according to the IEC 61674 standard requirements. In the saturation test, it was achieved in the whole voltage interval evaluated. For all pairs of voltages tested during the saturation determination, the polarity effect was within the recommended limit of ±1%, as stated by IEC 61674. The ion collection efficiency, in turn, was better than 99.99%. The special ionization chamber presented a linear behavior, with a regression coefficient of R2 = 0.9999. In the angular test, the maximum variation obtained was only 1.7%, so below the 3% recommended by the IEC 61674 standard. Results will also be presented about the energy dependence of the ionization chamber response in standard direct and attenuated mammography beams.

Como referenciar
SOARES, CLIMERIO S.; CALDAS, LINDA V.E. Evaluation of a special parallel-plate ionization chamber for mammography and digital breast tomosynthesis dosimetry. In: SIMPOSIO REPROLAM, 1st, November 5-8, 2024, Recife, PE. Abstract... Disponível em: https://repositorio.ipen.br/handle/123456789/48879. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento