Calibration of surface radioactive contamination detectors with beta and alpha radiation

dc.contributor.authorPOTIENS, M.P.A.pt_BR
dc.contributor.authorCOSTA, A.M.pt_BR
dc.contributor.authorCARVALHO, V.S.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 10thpt_BR
dc.date.accessioned2014-11-19T11:00:05Zpt_BR
dc.date.accessioned2014-11-19T14:03:07Zpt_BR
dc.date.accessioned2015-04-01T12:41:27Z
dc.date.available2014-11-19T11:00:05Zpt_BR
dc.date.available2014-11-19T14:03:07Zpt_BR
dc.date.available2015-04-01T12:41:27Z
dc.date.eventoSeptember 17-22, 2006pt_BR
dc.description.abstractThe Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares, IPEN, has already over 35 years been calibrating instruments used in radiation protection and therapy measurements that belongs to hospitals, industries, clinics and other users located in São Paulo state and in other parts of Brazil. At the present time, the Calibration Laboratory acts in the Radiation Protection, Radiation Therapy, Nuclear Medicine and Diagnostic Radiology areas, using special set-ups with gamma and beta radiation sealed sources, alpha and beta radiation plain sources and low and intermediate energies of X radiation. The instruments used in radiation protection measurements represent 88% of the tested instruments by the laboratory annually (approximately 1900). About 190 instruments are used in nuclear medicine clinics to detect surface radioactive contamination. The objective of this work is to present the results about this kind of calibration using alpha and beta radiation. The instruments normally used for surface contamination measurements are of pancake type Geiger tubes with very thin mica windows (2 mg.cm-2). They usually are sensitive to beta particles, with energies greater than 40 keV. They can also detect energetic alpha particles and gamma-rays. However, in this case the efficiency will be very different depending on the different radionuclides. The counting efficiency also depends on how close to the contaminated surface the detector is held. Surface contamination is usually expressed in units of radioactivity per area unit (Bq/m2 ) [1]. Other units such as picocuries per 100 cm2 or disintegrations per minute per square centimetre ae sometimes used. Special set-ups of plain beta (90Sr + 90Y, 99Tc, 36Cl and 137Cs) and alpha (241Am) sources were utilized. The surface emission rates varied from 406 to 1300 s-1, with an uncertainty of 5%. The instruments efficiencies obtained were between 0.02 to 0.45% for alpha radiation and 0.12 to 0.58 to beta radiation.
dc.event.siglaISRP10pt_BR
dc.identifier.citationPOTIENS, M.P.A.; COSTA, A.M.; CARVALHO, V.S.; CALDAS, L.V.E. Calibration of surface radioactive contamination detectors with beta and alpha radiation. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 10th, September 17-22, 2006, Coimbra, Portugal. <b>Abstract...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/20406.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/20406pt_BR
dc.local.eventoCoimbra, Portugalpt_BR
dc.rightsopenAccesspt_BR
dc.subjectamericium 241pt_BR
dc.subjectcalibrationpt_BR
dc.subjectcarbon 14pt_BR
dc.subjectcesium 137pt_BR
dc.subjectchlorine 36pt_BR
dc.subjectconfigurationpt_BR
dc.subjectdesignpt_BR
dc.subjectevaluationpt_BR
dc.subjectspatial distributionpt_BR
dc.subjectstrontium 90pt_BR
dc.subjectsurface contaminationpt_BR
dc.subjectsurfacespt_BR
dc.subjecttechnetium 99pt_BR
dc.subjectyttrium 90pt_BR
dc.titleCalibration of surface radioactive contamination detectors with beta and alpha radiationpt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorVALDIR DE SOUZA CARVALHO
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.codigoautor1495
ipen.codigoautor401
ipen.codigoautor346
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorVALDIR DE SOUZA CARVALHO
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.date.recebimento10-08pt_BR
ipen.event.datapadronizada2006pt_BR
ipen.identifier.ipendoc15516pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication387b23ee-5fb7-48e8-9ce5-0c42bccfe758
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication.latestForDiscovery30f213ae-321d-4d51-8763-0a2585255fb9
sigepi.autor.atividadePOTIENS, M.P.A.:346:28:Spt_BR
sigepi.autor.atividadeCARVALHO, V.S.:401:28:Npt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
15516.pdf
Tamanho:
15.07 KB
Formato:
Adobe Portable Document Format