Study of the gamma radiation response of watch glasses

dc.contributor.authorTEIXEIRA, MARIA I.pt_BR
dc.contributor.authorCOSTA, ZELIA M. dapt_BR
dc.contributor.authorCOSTA, CELIA R. dapt_BR
dc.contributor.authorPONTUSCHKA, WALTER M.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:43:46Zpt_BR
dc.date.accessioned2014-07-30T11:48:50Z
dc.date.available2014-07-15T13:43:46Zpt_BR
dc.date.available2014-07-30T11:48:50Z
dc.date.issued2008pt_BR
dc.description.abstractSome dosimetric properties of watch glasses were studied applying the thermoluminescence technique. The watch glass samples were powdered, and the selected grains were mixed with TeflonTM. The mixture was pressed and sintered to produce pellets of watch glass-TeflonTM composites. The glow curves of the pellets show two peaks at 130 and 195 {ring operator} C. Reproducibility of TL response was estimated to have a maximum coefficient of variation of 4.0%. The dose-response curve is sublinear between 0.5 and 20.0 kGy. The calibration curve is linear between 1.0 Gy and 1.0 kGy. The minimum detection limits were also determined. The gamma radiation dose response and the thermal stability of the materials were studied with the purpose to establish the best conditions of watch glasses for use in gamma radiation dosimetry.
dc.format.extent480-482pt_BR
dc.identifier.citationTEIXEIRA, MARIA I.; COSTA, ZELIA M. da; COSTA, CELIA R. da; PONTUSCHKA, WALTER M.; CALDAS, LINDA V.E. Study of the gamma radiation response of watch glasses. <b>Radiation Measurements</b>, v. 43, p. 480-482, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.radmeas.2007.11.029">10.1016/j.radmeas.2007.11.029</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5061.
dc.identifier.doi10.1016/j.radmeas.2007.11.029
dc.identifier.issn1350-4487pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5061pt_BR
dc.identifier.vol43pt_BR
dc.relation.ispartofRadiation Measurementspt_BR
dc.rightsopenAccessen
dc.subjectcalibrationpt_BR
dc.subjectdosimetrypt_BR
dc.subjectgamma radiationpt_BR
dc.subjectglasspt_BR
dc.subjectglow curvept_BR
dc.subjectpelletspt_BR
dc.subjectradiation dosespt_BR
dc.subjectthermoluminescencept_BR
dc.titleStudy of the gamma radiation response of watch glassespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorMARIA INES TEIXEIRA
ipen.codigoautor1495
ipen.codigoautor2431
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorMARIA INES TEIXEIRA
ipen.date.recebimento09-02pt_BR
ipen.identifier.fi1.267pt_BR
ipen.identifier.ipendoc13135pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication77e3728e-ac22-44ec-b407-8f95984cf27d
relation.isAuthorOfPublication.latestForDiscovery77e3728e-ac22-44ec-b407-8f95984cf27d
sigepi.autor.atividadeTEIXEIRA, MARIA I.:2431:330:Spt_BR
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13135.pdf
Tamanho:
166.24 KB
Formato:
Adobe Portable Document Format

Coleções