Assessment of the surface characteristics of ISO 5832-1 stainless steel for biomaterial applications

dc.contributor.authorPIERETTI, EURICO F.
dc.contributor.authorPIAGGIO, DAVIDE
dc.contributor.authorCOSTA, ISOLDA
dc.coverageInternacional
dc.date.accessioned2026-03-19T17:28:17Z
dc.date.available2026-03-19T17:28:17Z
dc.date.issued20256
dc.description.abstractMarking techniques are employed to guarantee the identification and traceability of biomedical materials. This study investigated the impact of laser and mechanical marking processes on the tribological performance of ISO 5832-1 austenitic stainless steel (SS), specifically examining corrosion resistance, the coefficient of friction, and wear volume in ball-cratering wear tests. The laser marking was performed using a nanosecond Q-switched Nd:YAG laser. Cytotoxicity tests assessed the biocompatibility of the biomaterial. Non-marked surfaces were also evaluated for comparison. A phosphate-buffered saline solution (PBS) served as both the lubricant and corrosion medium. The surface finishing was analyzed using optical microscopy and scanning electron microscopy coupled with a field-emission gun (SEM-FEG), combined with an energy-dispersive X-ray spectrometer. The oxide film was examined through X-ray photoelectron spectroscopy (XPS). Wear tests lasted 10 min, with PBS drops applied every 10 s at 75 rpm; solid balls of AISI 316L stainless steel (SS) and polypropylene (PP), each 1 inch in diameter, were used as counter-bodies. Corrosion resistance was assessed using electrochemical methods. Results showed variations in roughness and microstructure due to laser marking. The tribological behaviour was influenced by the type of marking process, and the wear amount depended on the normal force and ball nature. None of the samples was considered cytotoxic, although laser-marked surfaces exhibited the lowest cellular viability among the tested surfaces and the lowest corrosion resistance.
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIDCNPq: 443931/2023-2
dc.format.extent1-21
dc.identifier.doi10.3390/ma18174020
dc.identifier.fasciculo17
dc.identifier.issn1996-1944
dc.identifier.orcidhttps://orcid.org/0000-0002-4987-3334
dc.identifier.percentilfi58.8
dc.identifier.percentilfiCiteScore75.00
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/49511
dc.identifier.vol18
dc.language.isoeng
dc.relation.ispartofMaterials
dc.rightsopenAccess
dc.titleAssessment of the surface characteristics of ISO 5832-1 stainless steel for biomaterial applications
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorEURICO FELIX PIERETTI
ipen.autorISOLDA COSTA
ipen.codigoautor9762
ipen.codigoautor429
ipen.contributor.ipenauthorEURICO FELIX PIERETTI
ipen.contributor.ipenauthorISOLDA COSTA
ipen.identifier.fi3.2
ipen.identifier.fiCiteScore6.4
ipen.identifier.ipendoc31563
ipen.identifier.ods7
ipen.identifier.ods9
ipen.identifier.ods12
relation.isAuthorOfPublication81bdc39e-9843-47fe-bbed-2ab1670d694a
relation.isAuthorOfPublication952cc9fe-41a5-443f-b21a-316edc344ec8
relation.isAuthorOfPublication.latestForDiscovery81bdc39e-9843-47fe-bbed-2ab1670d694a

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
31563.pdf
Tamanho:
6.29 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções