Improving the RELAP5 code modeling of the siphon break effect in a pool type research reactor
Carregando...
Data
2024
Data de publicação:
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Concilium
Resumo
The pool water of a research reactor is used for emergency cooling of the reactor core. Siphon breakers are
installed in the lines of the Core Cooling System to stop the loss of water from the pool due to the siphon
effect during an accident involving piping ruptures. Previous studies discuss the effectiveness of siphon
breakers based on the air inlet area and question the ability of one-dimensional thermo-hydraulic codes to
model the siphon break devices. By means of comparison with experimental results, this work demonstrates
the ability of the RELAP5/MOD3.3 code to model the performance of the siphon breaker. There was
satisfactory agreement between the numerical and experimental results, showing that, as the air intake areas
of the siphons decrease, their effectiveness also decreases, resulting in greater drainage of the pool water.
For smaller air intake areas, the RELAP5/MOD3.3 code showed conservative results, overestimating the
reactor pool water losses.
Como referenciar
BELCHIOR JUNIOR, ANTONIO; SOARES, HUMBERTO V.; FREITAS, ROBERTO L.; MESQUITA, ROBERTO N. de; ROCHA, MARCELO da S.; ANDRADE, DELVONEI A. de. Improving the RELAP5 code modeling of the siphon break effect in a pool type research reactor. Concilium, v. 24, n. 11, p. 363-375, 2024. DOI: 10.53660/CLM-3531-24L08. Disponível em: https://repositorio.ipen.br/handle/123456789/48803. Acesso em: 16 Mar 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.