Development and tests of a 30cmpencil-type ionization chamber for dosimetry in standard and clinical CT beams
| dc.contributor.author | CASTRO, M.C. | |
| dc.contributor.author | SILVA, N.F. | |
| dc.contributor.author | XAVIER, M. | |
| dc.contributor.author | ANDRADE, M.E.A. | |
| dc.contributor.author | KHOURY, H.J. | |
| dc.contributor.author | CALDAS, L.V.E. | |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2018-02-07T12:35:52Z | |
| dc.date.available | 2018-02-07T12:35:52Z | |
| dc.date.issued | 2017 | pt_BR |
| dc.description.abstract | The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology. To perform the dosimetry inCT beams, the most widely used instrument is the pencil type ionization chamber with a sensitive volume length of 100 mm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study an ionization chamber with sensitive volume length of 300mmwas developed at IPEN. The characterization of this chamber was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chamber was tested in clinical beams of two different hospitals. | pt_BR |
| dc.format.extent | 1-7 | pt_BR |
| dc.identifier.citation | CASTRO, M.C.; SILVA, N.F.; XAVIER, M.; ANDRADE, M.E.A.; KHOURY, H.J.; CALDAS, L.V.E. Development and tests of a 30cmpencil-type ionization chamber for dosimetry in standard and clinical CT beams. <b>Biomedical Physics & Engineering Express</b>, v. 3, n. 5, p. 1-7, 2017. DOI: <a href="https://dx.doi.org/10.1088/2057-1976/aa82e3">10.1088/2057-1976/aa82e3</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/28457. | |
| dc.identifier.doi | 10.1088/2057-1976/aa82e3 | pt_BR |
| dc.identifier.fasciculo | 5 | pt_BR |
| dc.identifier.issn | 2057-1976 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.percentilfi | Sem Percentil | en |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/28457 | |
| dc.identifier.vol | 3 | pt_BR |
| dc.relation.ispartof | Biomedical Physics & Engineering Express | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | computerized tomography | |
| dc.subject | ionization chambers | |
| dc.subject | dosimetry | |
| dc.subject | calibration | |
| dc.title | Development and tests of a 30cmpencil-type ionization chamber for dosimetry in standard and clinical CT beams | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | MARCOS XAVIER | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | NATALIA FIORINI DA SILVA | |
| ipen.autor | MAYSA COSTA DE CASTRO | |
| ipen.codigoautor | 712 | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 12139 | |
| ipen.codigoautor | 12105 | |
| ipen.contributor.ipenauthor | MARCOS XAVIER | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | NATALIA FIORINI DA SILVA | |
| ipen.contributor.ipenauthor | MAYSA COSTA DE CASTRO | |
| ipen.date.recebimento | 18-02 | pt_BR |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 24229 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | d0233a99-c67a-41f8-9d92-cbce7c44a54e | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | c8a4b1ff-5955-47b9-a15a-ecbd12a4baa8 | |
| relation.isAuthorOfPublication | a7ec93af-7e13-4572-8409-2fcafeab7015 | |
| relation.isAuthorOfPublication.latestForDiscovery | a7ec93af-7e13-4572-8409-2fcafeab7015 | |
| sigepi.autor.atividade | CASTRO, M.C.:12105:330:S | pt_BR |
| sigepi.autor.atividade | SILVA, N.F.:12139:330:N | pt_BR |
| sigepi.autor.atividade | XAVIER, M.:712:330:N | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:330:N | pt_BR |