Assessment of bone dose response using ATR-FTIR spectroscopy

dc.contributor.authorCASTRO, PEDRO A.A. dept_BR
dc.contributor.authorDIAS, DERLY A.pt_BR
dc.contributor.authorDEL-VALLE, MATHEUSpt_BR
dc.contributor.authorVELOSO, MARCELO N.pt_BR
dc.contributor.authorSOMESSARI, ELIZABETH S.R.pt_BR
dc.contributor.authorZEZELL, DENISE M.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2022-08-15T19:32:39Z
dc.date.available2022-08-15T19:32:39Z
dc.date.issued2022pt_BR
dc.description.abstractThe health care application of ionizing radiation has expanded worldwide during the last several decades. While the health impacts of ionizing radiation improved patient care, inaccurate handling of radiation technology is more prone to potential health risks. Therefore, the present study characterizes the bone dose response using bovine femurs from a slaughterhouse. The gamma irradiation was designed into low-doses (0.002, 0.004 and 0.007 kGy) and high-doses (1, 10, 15, 25, 35, 50 and 60 kGy), all samples received independent doses. The combination of FTIR spectroscopy and PLS-DA allows the detection of differences in the control group and the ionizing dose, as well as distinguishing between high and low radiation doses. In this way, our findings contribute to future studies of the dose response to track ionizing radiation effects on biological systems.pt_BR
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipIDFAPESP: 17/50332-0; 21/00633-0pt_BR
dc.description.sponsorshipIDCAPES: 001; PROCAD 88881.068505/2014-01pt_BR
dc.description.sponsorshipIDCNPq: INCT-465763/2014-6; Sisfoton 440228/2021-2; PQ-309902/2017-7; PhD-grant-141946/2018-0; 142229/2019-9pt_BR
dc.format.extent1-7pt_BR
dc.identifier.citationCASTRO, PEDRO A.A. de; DIAS, DERLY A.; DEL-VALLE, MATHEUS; VELOSO, MARCELO N.; SOMESSARI, ELIZABETH S.R.; ZEZELL, DENISE M. Assessment of bone dose response using ATR-FTIR spectroscopy: a potential method for biodosimetry. <b>Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy</b>, v. 273, p. 1-7, 2022. DOI: <a href="https://dx.doi.org/10.1016/j.saa.2022.120900">10.1016/j.saa.2022.120900</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/33215.
dc.identifier.doi10.1016/j.saa.2022.120900pt_BR
dc.identifier.issn1386-1425pt_BR
dc.identifier.orcid0000-0001-7404-9606pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7404-9606
dc.identifier.percentilfi89pt_BR
dc.identifier.percentilfiCiteScore85.75pt_BR
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/33215
dc.identifier.vol273pt_BR
dc.relation.ispartofSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopypt_BR
dc.rightsopenAccesspt_BR
dc.subjectionizing radiations
dc.subjectradiation doses
dc.subjectdosimetry
dc.subjectskeleton
dc.subjectbiological dosemeters
dc.subjectfourier transformation
dc.subjectinfrared radiation
dc.titleAssessment of bone dose response using ATR-FTIR spectroscopypt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorDERLY AUGUSTO DIAS
ipen.autorMARCELO NORONHA VELOSO
ipen.autorDENISE MARIA ZEZELL
ipen.autorELIZABETH SEBASTIANA RIBEIRO SOMESSARI
ipen.autorMATHEUS DEL VALLE
ipen.autorPEDRO ARTHUR AUGUSTO DE CASTRO
ipen.codigoautor12688
ipen.codigoautor9771
ipen.codigoautor693
ipen.codigoautor1544
ipen.codigoautor15209
ipen.codigoautor12053
ipen.contributor.ipenauthorDERLY AUGUSTO DIAS
ipen.contributor.ipenauthorMARCELO NORONHA VELOSO
ipen.contributor.ipenauthorDENISE MARIA ZEZELL
ipen.contributor.ipenauthorELIZABETH SEBASTIANA RIBEIRO SOMESSARI
ipen.contributor.ipenauthorMATHEUS DEL VALLE
ipen.contributor.ipenauthorPEDRO ARTHUR AUGUSTO DE CASTRO
ipen.date.recebimento22-08
ipen.identifier.fi4.4pt_BR
ipen.identifier.fiCiteScore7.9pt_BR
ipen.identifier.ipendoc28871pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi75.00 - 100.00
ipen.subtituloa potential method for biodosimetrypt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationfdbcd2db-5942-471b-9866-52f8006edd28
relation.isAuthorOfPublication570f64d7-3caf-4e8e-9a56-a436d477e711
relation.isAuthorOfPublicationa565f8ad-3432-4891-98c0-a587f497db21
relation.isAuthorOfPublication155e1a85-0635-407b-920c-00af43266aca
relation.isAuthorOfPublicationfdd01116-8cc4-406a-aafb-606941dc28dc
relation.isAuthorOfPublication4fc30bdc-40c6-4bd5-9431-96db978a0475
relation.isAuthorOfPublication.latestForDiscovery4fc30bdc-40c6-4bd5-9431-96db978a0475
sigepi.autor.atividadeZEZELL, DENISE M.:693:920:Npt_BR
sigepi.autor.atividadeSOMESSARI, ELIZABETH S.R.:1544:220:Npt_BR
sigepi.autor.atividadeVELOSO, MARCELO N.:9771:-1:Npt_BR
sigepi.autor.atividadeDEL-VALLE, MATHEUS:15209:920:Npt_BR
sigepi.autor.atividadeDIAS, DERLY A.:12688:-1:Npt_BR
sigepi.autor.atividadeCASTRO, PEDRO A.A. de:12053:930:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
28871.pdf
Tamanho:
1.41 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções