| dc.description.abstract | A tandem ionization chamber was developed for quality control programs of the kilovoltage X-ray equipment used in radiotherapy. This chamber was tested and calibrated in low-energy X-ray beams in accordance with international recommendations, and it showed a satisfactory level of performance, mainly with regard to its main use, namely formation of a tandem system for confirmation of half-value layers in X-radiation beams previously determined by the conventional method. In this developed system no absorbers or special setups are necessary. | |
| dc.format.extent | 495-500 | pt_BR |
| dc.identifier.citation | COSTA, A.M.; CALDAS, L.V.E. Response characteristics of a tandem ionization chamber in standard X-ray beams. <b>Applied Radiation and Isotopes</b>, v. 58, n. 4, p. 495-500, 2003. DOI: <a href="https://dx.doi.org/10.1016/S0969-8043(03)00026-5">10.1016/S0969-8043(03)00026-5</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5887. | |
| dc.identifier.doi | 10.1016/S0969-8043(03)00026-5 | |
| dc.identifier.fasciculo | 4 | pt_BR |
| dc.identifier.issn | 0969-8043 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5887 | pt_BR |
| dc.identifier.vol | 58 | pt_BR |
| dc.relation.ispartof | Applied Radiation and Isotopes | pt_BR |
| dc.rights | openAccess | en |
| dc.subject | ionization chambers | pt_BR |
| dc.subject | quality control | pt_BR |
| dc.subject | x-ray equipment | pt_BR |
| dc.subject | x radiation | pt_BR |
| dc.subject | calibration | pt_BR |
| dc.subject | performance | pt_BR |
| dc.title | Response characteristics of a tandem ionization chamber in standard X-ray beams | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.autor | ALESSANDRO MARTINS DA COSTA | |
| ipen.codigoautor | 1495 | |
| ipen.codigoautor | 2085 | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.contributor.ipenauthor | ALESSANDRO MARTINS DA COSTA | |
| ipen.date.recebimento | 03-06 | pt_BR |
| ipen.identifier.fi | 0.690 | pt_BR |
| ipen.identifier.ipendoc | 08963 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication | a6ba2d23-3602-4408-a91a-42afff4c4677 | |
| relation.isAuthorOfPublication.latestForDiscovery | a6ba2d23-3602-4408-a91a-42afff4c4677 | |
| sigepi.autor.atividade | COSTA, A.M.:2085:-1:S | pt_BR |
| sigepi.autor.atividade | CALDAS, L.V.E.:1495:28:N | pt_BR |
Pacote Original
1 - 1 de 1