Dosimetric characterization of high-linearity bone radiation detector exposed to gamma-rays

Carregando...
Imagem de Miniatura

Data

Data de publicação

2019

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

É parte de

INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
Introduction In radiation physics, the study of new alternative dosimeters is of interest on the growing branch of dosimetric characterization of solid-state dosimeters for radiotherapy applications in the Medical Physics fi elds. There are innumerous emerging techniques for reading and processing multivariate data to assess the possible linear behavior of dosimeters; such methods are the multivariate calibration Partial Least Square Regression (PLSR) and Principle Component Regression (PCR) techniques. The goal of this work was to expose bone samples to high doses and to use the FTIR spectrophotometry technique to evaluate the sensitivity and linearity of the absorbed profi les using PLSR and PCR analyses. Methods Small cubes with size approximately of 0.5 cm3 composed the bone samples, used in this work. The samples were irradiated in triplicates, with absorbed doses of 10, 100, 250, 400 and 500 Gy using a 60Co Gamma Cell-220 system (dose rate of 1.089 kGy/h); afterwards, the absorbance spectrum of each sample was acquired on a Fourier Transform Infrared (FTIR) Spectrometer (Frontier/Perkin Elmer) with an optical step of 1 nm from 400 nm to 4000 nm. Results The absorbance for high sensitivity peaks was observed for each bone sample, at the 552 nm, 991 nm and 1650 nm wavelengths in decreasing magnitude. The PLSR and PCR techniques showed, on the range from 10 Gy to 500 Gy, for the calibration curves of the system, a linearity of 0.9432 and 0.9422 respectively, using just three components on both methods. Conclusions The results indicate an acceptable linear response, and therefore this material may be an interesting radiation detector.

Como referenciar
OLIVEIRA, LUCAS N. de; NASCIMENTO, ERIBERTO O.; MORAIS JUNIOR, PEDRO A.; ANTONIO, PATRICIA L.; CALDAS, LINDA V.E. Dosimetric characterization of high-linearity bone radiation detector exposed to gamma-rays. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. Abstract... Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/31017. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.

Agência de fomento