Dosimetric characterization of high-linearity bone radiation detector exposed to gamma-rays

dc.contributor.authorOLIVEIRA, LUCAS N. dept_BR
dc.contributor.authorNASCIMENTO, ERIBERTO O.pt_BR
dc.contributor.authorMORAIS JUNIOR, PEDRO A.pt_BR
dc.contributor.authorANTONIO, PATRICIA L.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rdpt_BR
dc.date.accessioned2020-03-31T18:54:35Z
dc.date.available2020-03-31T18:54:35Z
dc.date.eventoMay 27-31, 2019pt_BR
dc.description.abstractIntroduction In radiation physics, the study of new alternative dosimeters is of interest on the growing branch of dosimetric characterization of solid-state dosimeters for radiotherapy applications in the Medical Physics fi elds. There are innumerous emerging techniques for reading and processing multivariate data to assess the possible linear behavior of dosimeters; such methods are the multivariate calibration Partial Least Square Regression (PLSR) and Principle Component Regression (PCR) techniques. The goal of this work was to expose bone samples to high doses and to use the FTIR spectrophotometry technique to evaluate the sensitivity and linearity of the absorbed profi les using PLSR and PCR analyses. Methods Small cubes with size approximately of 0.5 cm3 composed the bone samples, used in this work. The samples were irradiated in triplicates, with absorbed doses of 10, 100, 250, 400 and 500 Gy using a 60Co Gamma Cell-220 system (dose rate of 1.089 kGy/h); afterwards, the absorbance spectrum of each sample was acquired on a Fourier Transform Infrared (FTIR) Spectrometer (Frontier/Perkin Elmer) with an optical step of 1 nm from 400 nm to 4000 nm. Results The absorbance for high sensitivity peaks was observed for each bone sample, at the 552 nm, 991 nm and 1650 nm wavelengths in decreasing magnitude. The PLSR and PCR techniques showed, on the range from 10 Gy to 500 Gy, for the calibration curves of the system, a linearity of 0.9432 and 0.9422 respectively, using just three components on both methods. Conclusions The results indicate an acceptable linear response, and therefore this material may be an interesting radiation detector.pt_BR
dc.event.siglaICDApt_BR
dc.identifier.citationOLIVEIRA, LUCAS N. de; NASCIMENTO, ERIBERTO O.; MORAIS JUNIOR, PEDRO A.; ANTONIO, PATRICIA L.; CALDAS, LINDA V.E. Dosimetric characterization of high-linearity bone radiation detector exposed to gamma-rays. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. <b>Abstract...</b> Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/31017.
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/31017
dc.localLisboa, Portugalpt_BR
dc.local.eventoLisboa, Portugalpt_BR
dc.publisherC2TN, Instituto Superior Técnico, Universidade de Lisboapt_BR
dc.rightsopenAccesspt_BR
dc.titleDosimetric characterization of high-linearity bone radiation detector exposed to gamma-rayspt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorPATRICIA DE LARA ANTONIO
ipen.autorLUCAS NONATO DE OLIVEIRA
ipen.codigoautor1495
ipen.codigoautor6585
ipen.codigoautor10632
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorPATRICIA DE LARA ANTONIO
ipen.contributor.ipenauthorLUCAS NONATO DE OLIVEIRA
ipen.date.recebimento20-03
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26812pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication5ea4ca8b-8415-4439-81d2-6fe0d6debd42
relation.isAuthorOfPublication87cc29f4-0e1f-4f7f-87ab-618b39834eb2
relation.isAuthorOfPublication.latestForDiscovery87cc29f4-0e1f-4f7f-87ab-618b39834eb2
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeANTONIO, PATRICIA L.:6585:330:Npt_BR
sigepi.autor.atividadeOLIVEIRA, LUCAS N. de:10632:330:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26812.pdf
Tamanho:
171.64 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: