Performance evaluation of a new dosimetric system for lens dosimetry made using 3D printing

dc.contributor.authorNASCIMENTO, G.G.
dc.contributor.authorRODRIGUES JUNIOR, O.
dc.contributor.authorSAVI, M.
dc.contributor.authorVILLANI, D.
dc.contributor.authorPOTIENS, M.P.A.
dc.coverageInternacional
dc.date.accessioned2026-02-20T12:44:36Z
dc.date.available2026-02-20T12:44:36Z
dc.date.issued2025
dc.description.abstractFor some years now, the radiation dose received by the lens of the eye has been the subject of discussion in the field of radiological protection. As a result, dose limits have been reduced, and the lens has come to be considered a critical organ. This concern has become more intense in the interventional radiology environment, where occupational exposure is significant, increasing the likelihood of developing cataracts caused by radiation. The present study aims to evaluate the performance of a new model of dosimeter holder, manufactured by means of 3D printing, designed for lens dosimetry, comparing its performance using a cylinder phantom recommended by ICRU and an anthropomorphic simulator developed by 3D printing.
dc.description.sponsorshipFundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPQ)
dc.description.sponsorshipIDFAPESP: 17/50332-0
dc.description.sponsorshipIDCNPQ: 140973/2023-0
dc.format.extent1-6
dc.identifier.citationNASCIMENTO, G.G.; RODRIGUES JUNIOR, O.; SAVI, M.; VILLANI, D.; POTIENS, M.P.A. Performance evaluation of a new dosimetric system for lens dosimetry made using 3D printing. <b>Radiation Physics and Chemistry</b>, v. 232, p. 1-6, 2025. DOI: <a href="https://dx.doi.org/10.1016/j.radphyschem.2025.112701">10.1016/j.radphyschem.2025.112701</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/49332.
dc.identifier.doi10.1016/j.radphyschem.2025.112701
dc.identifier.issn0969-806X
dc.identifier.orcidhttps://orcid.org/0000-0002-6704-1910
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.percentilfi74.4
dc.identifier.percentilfiCiteScore88.00
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/49332
dc.identifier.vol232
dc.language.isoeng
dc.relation.ispartofRadiation Physics and Chemistry
dc.rightsopenAccess
dc.titlePerformance evaluation of a new dosimetric system for lens dosimetry made using 3D printing
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorGABRIEL GOMES DO NASCIMENTO
ipen.autorORLANDO RODRIGUES JUNIOR
ipen.autorDANIEL VILLANI
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.codigoautor14794
ipen.codigoautor322
ipen.codigoautor12762
ipen.codigoautor346
ipen.contributor.ipenauthorGABRIEL GOMES DO NASCIMENTO
ipen.contributor.ipenauthorORLANDO RODRIGUES JUNIOR
ipen.contributor.ipenauthorDANIEL VILLANI
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.identifier.fi3.3
ipen.identifier.fiCiteScore5.6
ipen.identifier.ipendoc31449
ipen.identifier.iwosWoS
ipen.range.fi3.000 - 4.499
ipen.range.percentilfi50.00 - 74.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationef601e21-998c-4d4d-9aee-c0f8dbc84c10
relation.isAuthorOfPublicationf72d59d1-f942-442a-b16e-8b0ba0e2b671
relation.isAuthorOfPublication26698252-02e7-4d43-8ffb-edaf9f863fa2
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication.latestForDiscoveryef601e21-998c-4d4d-9aee-c0f8dbc84c10
sigepi.autor.atividadeGABRIEL GOMES DO NASCIMENTO:14794:330:N
sigepi.autor.atividadeORLANDO RODRIGUES JUNIOR:322:330:N
sigepi.autor.atividadeDANIEL VILLANI:12762:330:N
sigepi.autor.atividadeMARIA DA PENHA ALBUQUERQUE POTIENS:346:330:N

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
31449.pdf
Tamanho:
5.31 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções