Intrinsic efficiency of CaSO4:Dy to electron beams

dc.contributor.authorNUNES, M.G.pt_BR
dc.contributor.authorCAMPOS, L.L.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:38:02Zpt_BR
dc.date.accessioned2014-07-30T11:46:40Z
dc.date.available2014-07-15T13:38:02Zpt_BR
dc.date.available2014-07-30T11:46:40Z
dc.date.issued2010pt_BR
dc.description.abstractThe intrinsic efficiency of CaSO4 :Dy thermoluminescent dosimeters, developed by Instituto de Pesquisas Energéticas e Nucleares – IPEN was calculated for 3.43, 5.48, 8.27, 11.67 and 15.42 MeV clinical electron beams at their depth of maximum ionization in polymethyl methacrylate (PMMA), SW Solid Water and standard water phantoms. The sensitivity, varying from 14.6 ± 0.3 mC.Gy-1 (11.67 MeV, PMMA) to 19.6 ± 0.5 mC.Gy-1 (15.42 MeV, water), the reproducibility of the TL response, better than 2.4%, and the TL response as a function of the dose, linear between 0.01 and 3.25 Gy, were also evaluated. The intrinsic efficiency of 0.0342 ± 0.0021 % indicates that CaSO4 :Dy dosimeters can be applied to the radiation protection for high energy electron beams generated by linear accelerators.
dc.format.extent106-112pt_BR
dc.identifier.citationNUNES, M.G.; CAMPOS, L.L. Intrinsic efficiency of CaSO4:Dy to electron beams. <b>Radioproteção</b>, v. 2, n. 16-17, p. 106-112, 2010. Disponível em: http://repositorio.ipen.br/handle/123456789/4524.
dc.identifier.fasciculo16-17pt_BR
dc.identifier.issn0874-7016pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/4524pt_BR
dc.identifier.vol2pt_BR
dc.relation.ispartofRadioproteçãopt_BR
dc.rightsopenAccessen
dc.subjectcalcium sulfatespt_BR
dc.subjectdysprosiumpt_BR
dc.subjectthermoluminescent dosimetrypt_BR
dc.subjectelectron beamspt_BR
dc.subjectionizationpt_BR
dc.subjectpmmapt_BR
dc.subjectlinear acceleratorspt_BR
dc.titleIntrinsic efficiency of CaSO4:Dy to electron beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorMAIRA GOES NUNES
ipen.codigoautor1195
ipen.codigoautor3897
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorMAIRA GOES NUNES
ipen.date.recebimento13-04pt_BR
ipen.identifier.fiSem F.I.pt_BR
ipen.identifier.ipendoc18978pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication384beabb-178e-473f-957c-e699b3f15af7
relation.isAuthorOfPublication.latestForDiscovery384beabb-178e-473f-957c-e699b3f15af7
sigepi.autor.atividadeNUNES, M.G.:3897:330:Spt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
18978.pdf
Tamanho:
2.26 MB
Formato:
Adobe Portable Document Format

Coleções