Autoclaving and battery capacity influence on laser fluorescence measurements

dc.contributor.authorCABRAL, RENATA M.R.pt_BR
dc.contributor.authorMENDES, FAUSTO M.pt_BR
dc.contributor.authorMIURA, FABIANApt_BR
dc.contributor.authorRIBEIRO, ADRIANA da C.pt_BR
dc.contributor.authorBRAGA, MARIANA M.pt_BR
dc.contributor.authorZEZELL, DENISE M.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:43:14Zpt_BR
dc.date.accessioned2014-07-30T11:50:12Z
dc.date.available2014-07-15T13:43:14Zpt_BR
dc.date.available2014-07-30T11:50:12Z
dc.date.issued2008pt_BR
dc.description.abstractAim. To evaluate the influence of probe tip autoclaving and depleted alkaline batteries on laser fluorescence (LF-DIAGNOdent) device performance. Material and methods. One-hundred-and-twenty occlusal sites were analyzed with an LF device in nine conditions: No autoclaved probe and probe after 5, 10, 15, 20, 25, 30, 40, and 50 autoclaving cycles. Subsequently, the performance of the device was analyzed with: New batteries, batteries with 1.49/1.39 V, 1.38/1.37 V, 1.36/1.34 V, 1.33/1.32 V, and lower than 1.32 V. LF values, sensitivity, specificity, accuracy, and area under the ROC curve were compared. Results. In the probe study, sensitivity was lower after 50 sterilizing cycles, though specificity was higher than the assessment performed using a new tip. In the batteries study, specificity was higher for depleted batteries, but LF performance did not differ significantly among the groups. Conclusion. Batteries do not significantly influence device performance, but consecutive sterilization of probes in autoclave alters readings, downgrading its performance.
dc.format.extent122-127pt_BR
dc.identifier.citationCABRAL, RENATA M.R.; MENDES, FAUSTO M.; MIURA, FABIANA; RIBEIRO, ADRIANA da C.; BRAGA, MARIANA M.; ZEZELL, DENISE M. Autoclaving and battery capacity influence on laser fluorescence measurements. <b>Acta Odontologica Scandinavica</b>, v. 66, p. 122-127, 2008. DOI: <a href="https://dx.doi.org/10.1080/00016350802017484">10.1080/00016350802017484</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5010.
dc.identifier.doi10.1080/00016350802017484
dc.identifier.issn0001-6357pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-7404-9606
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5010pt_BR
dc.identifier.vol66pt_BR
dc.relation.ispartofActa Odontologica Scandinavicapt_BR
dc.rightsclosedAccessen
dc.subjectdentistrypt_BR
dc.subjectlaserspt_BR
dc.subjectfluorescencept_BR
dc.subjectautoclavespt_BR
dc.titleAutoclaving and battery capacity influence on laser fluorescence measurementspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorDENISE MARIA ZEZELL
ipen.autorRENATA MACIEL E ROCHA CABRAL
ipen.codigoautor693
ipen.codigoautor3252
ipen.contributor.ipenauthorDENISE MARIA ZEZELL
ipen.contributor.ipenauthorRENATA MACIEL E ROCHA CABRAL
ipen.date.recebimento09-02pt_BR
ipen.identifier.fi1.095pt_BR
ipen.identifier.ipendoc13211pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublicationa565f8ad-3432-4891-98c0-a587f497db21
relation.isAuthorOfPublicationc6ffdf39-d9b6-4144-8d55-3dbf94f05c93
relation.isAuthorOfPublication.latestForDiscoveryc6ffdf39-d9b6-4144-8d55-3dbf94f05c93
sigepi.autor.atividadeCABRAL, RENATA M.R.:3252:-1:Spt_BR
sigepi.autor.atividadeZEZELL, DENISE M.:693:920:Npt_BR