A novel rectal applicator for contact radiotherapy with HDR 192Ir sources

dc.contributor.authorBELLEZZO, MURILLO
dc.contributor.authorFONSECA, GABRIEL P.
dc.contributor.authorVERRIJSSEN, AN-SOFIE
dc.contributor.authorVONCKEN, ROBERT
dc.contributor.authorBOSCH, MICHIEL R.V. den
dc.contributor.authorYORIYAZ, HELIO
dc.contributor.authorRENIERS, BRIGITTE
dc.contributor.authorBERBEE, MAAIKE
dc.contributor.authorLIMBERGEN, EVERT J.V.
dc.contributor.authorVERHAEGEN, FRANK
dc.coverageInternacionalpt_BR
dc.date.accessioned2018-11-22T17:48:40Z
dc.date.available2018-11-22T17:48:40Z
dc.date.issued2018pt_BR
dc.description.abstractPURPOSE: Dose escalation to rectal tumors leads to higher complete response rates and may thereby enable omission of surgery. Important advantages of endoluminal boosting techniques include the possibility to apply a more selective/localized boost than using external beam radiotherapy. A novel brachytherapy (BT) rectal applicator with lateral shielding was designed to be used with a rectoscope for eye-guided positioning to deliver a dose distribution similar to the one of contact x-ray radiotherapy devices, using commonly available high-dose-rate 192Ir BT sources. METHODS AND MATERIALS: A cylindrical multichannel BT applicator with lateral shielding was designed by Monte Carlo modeling, validated experimentally with film dosimetry and compared with results found in the literature for the Papillon 50 (P50) contact x-ray radiotherapy device regarding rectoscope dimensions, radiation beam shape, dose fall-off, and treatment time. RESULTS: The multichannel applicator designed is able to deliver 30 Gy under 13 min with a 20350 U (5 Ci) source. The use of multiple channels and lateral shielding provide a uniform circular treatment surface with 22 mm in diameter. The resulting dose fall-off is slightly steeper (maximum difference of 5%) than the one generated by the P50 device with the 22 mm applicator. CONCLUSIONS: A novel multichannel rectal applicator for contact radiotherapy with high-doserate 192Ir sources that can be integrated with commercially available treatment planning systems was designed to produce a dose distribution similar to the one obtained by the P50 device.pt_BR
dc.format.extent1037-1044pt_BR
dc.identifier.citationBELLEZZO, MURILLO; FONSECA, GABRIEL P.; VERRIJSSEN, AN-SOFIE; VONCKEN, ROBERT; BOSCH, MICHIEL R.V. den; YORIYAZ, HELIO; RENIERS, BRIGITTE; BERBEE, MAAIKE; LIMBERGEN, EVERT J.V.; VERHAEGEN, FRANK. A novel rectal applicator for contact radiotherapy with HDR 192Ir sources. <b>Brachytherapy</b>, v. 17, n. 6, p. 1037-1044, 2018. DOI: <a href="https://dx.doi.org/10.1016/j.brachy.2018.07.012">10.1016/j.brachy.2018.07.012</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/29271.
dc.identifier.doi10.1016/j.brachy.2018.07.012pt_BR
dc.identifier.fasciculo6pt_BR
dc.identifier.issn1538-4721pt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidaguardandopt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4023-236X
dc.identifier.percentilfi34.09pt_BR
dc.identifier.percentilfiCiteScore53.50
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/29271
dc.identifier.vol17pt_BR
dc.relation.ispartofBrachytherapypt_BR
dc.rightsopenAccesspt_BR
dc.subjectradiotherapy
dc.subjectlarge intestine
dc.subjectrectum
dc.subjectneoplasms
dc.subjectmonte carlo method
dc.subjectbrachytherapy
dc.subjectdose rates
dc.subjectiridium 192
dc.titleA novel rectal applicator for contact radiotherapy with HDR 192Ir sourcespt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorMURILLO BELLEZZO
ipen.autorHELIO YORIYAZ
ipen.codigoautor10246
ipen.codigoautor80
ipen.contributor.ipenauthorMURILLO BELLEZZO
ipen.contributor.ipenauthorHELIO YORIYAZ
ipen.date.recebimento18-11pt_BR
ipen.identifier.fi2.030pt_BR
ipen.identifier.fiCiteScore3.4
ipen.identifier.ipendoc25053pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi1.500 - 2.999
ipen.range.percentilfi25.00 - 49.99
ipen.type.genreArtigo
relation.isAuthorOfPublicationfbb6d3c2-9f6b-43d0-947e-d4de7792bee3
relation.isAuthorOfPublication93102dac-f89d-4743-b6ea-5158708cbb92
relation.isAuthorOfPublication.latestForDiscoveryfbb6d3c2-9f6b-43d0-947e-d4de7792bee3
sigepi.autor.atividadeBELLEZZO, MURILLO:10246:420:Spt_BR
sigepi.autor.atividadeYORIYAZ, HELIO:80:420:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
25053.pdf
Tamanho:
1.03 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções